Payne INDUCED COMBUSTION GAS FURNACE Owner's Manual
Payne INDUCED COMBUSTION GAS FURNACE Owner's Manual

Payne INDUCED COMBUSTION GAS FURNACE Owner's Manual

Induced combustion gas furnace

Advertisement

Quick Links

NOTE TO INSTALLER:
THIS MANUAL MUST BE LEFT WITH THE
EQUIPMENT USER.
USER: PLEASE READ ALL INSTRUCTIONS
IN THE MANUAL AND RETAIN ALL
MANUALS FOR FUTURE REFERENCE.
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow warnings could result in injury, death,
or property damage.
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
- -Do not try to light any appliance.
- -Do not touch any electrical switch; do not use any
phone in your building.
- -Leave the building immediately.
- -Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
- -If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
WARNING
!
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal
injury and/or death.
Carbon Monoxide is invisible, odorless, and toxic!
Payne Heating and Cooling Systems recommends a
carbon monoxide alarm in your home, even if you do
not own a gas appliance. Locate the carbon monoxide
alarm in the living area of your home and away from
gas appliances and doorways to attached garages.
Follow the alarm manufacturer's instruction included
with the alarm.
INDUCED COMBUSTION GAS FURNACE
Owner's Manual
1
WARNING
!
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury,
death, or property damage.
Do not use this furnace if any part has been under water. A
flood- -damaged furnace is extremely dangerous. Attempts to
use the furnace can result in fire or explosion. A qualified
service agency should be contacted to inspect the furnace and
to replace all gas controls, control system parts, electrical parts
that have been wet or the furnace if deemed necessary.
CERTIFIED
A08174

Advertisement

Table of Contents
loading

Summary of Contents for Payne INDUCED COMBUSTION GAS FURNACE

  • Page 1: Combustible Materials, Gasoline Warning

    Carbon Monoxide is invisible, odorless, and toxic! Do not use this furnace if any part has been under water. A Payne Heating and Cooling Systems recommends a flood- -damaged furnace is extremely dangerous. Attempts to carbon monoxide alarm in your home, even if you do use the furnace can result in fire or explosion.
  • Page 2: Table Of Contents

    WELCOME TO TODAY’S GENERATION INDUCER MOTOR VENT ELBOW ASSEMBLY OF COMFORT MAIN LIMIT SWITCH (BEHIND GAS VALVE) Congratulations! Your new, higher efficiency gas furnace is a PRESSURE SWITCH DRAFT sound investment which will reward you and your family with SAFEGUARD FLUE SWITCH years of warm memories winter after winter.
  • Page 3: Safety Considerations

    STARTING YOUR FURNACE This furnace contains safety devices which must be manually reset. If the furnace is left unattended for an extended period of time, Your furnace uses an automatic, hot surface ignition system to light have it checked periodically for proper operation. This precaution the burners each time the thermostat signals the furnace to start.
  • Page 4: Starting (Lighting) And Shutting Down The Furnace Warning

    A02267 A06188 Fig. 8 - - Control Switch to ON Fig. 4 - - Close Valve 8. Replace the outer door and tighten the thumbscrew. See Fig. 3. Turn OFF electrical supply to the furnace. See Fig. 5. A92185 Fig. 5 - - Turn Off Electrical Supply 4.
  • Page 5: Shutting Down Your Furnace

    the furnace’s heat exchanger. After a time delay of approxim- CAUTION ately 25- -45 seconds the furnace blower is switched on. NOTE: If the main burners fail to ignite, the furnace control CUT HAZARD system will go through three more ignition cycles. Then if burners fail to ignite, the system will lockout.
  • Page 6: Combustion Area And Vent System

    FILTER QUANTITY AND SIZE * FURNACE CASING WIDTH FILTER TYPE* IN (MM) SIDE RETURN BOTTOM RETURN IN (MM) IN (MM) 3/4” (19 mm) thick washable or (1) 16 x 25 (1) 14 x 25 14--- 1/2 (368) 4--- 5/16” (110 mm) thick (406 x 635) (356 x 635) media--- type...
  • Page 7: Before You Request A Service Call

    4. Restore electrical power to the furnace. (See Fig. 10.) S Check the manual reset limit switches located on the ends of the 5. Start the furnace and observe its operation. If possible, burner enclosure (see Fig. 1 and 2). If the furnace has watch the burner flames.
  • Page 8: Installation Data

    _____________________________________________ NOTE TO INSTALLER: This manual must be left with the equipment owner. Catalog No: OG ---PG8M---05 E2008 Payne Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 12/08 Replaces: OG--- PG8M--- 04...

This manual is also suitable for:

Pg8m

Table of Contents