tRoUbLEShootiNg tAbLE
If you run into a problem, refer to the troubleshooting table below.
Symptom
The refrigerator has stopped
cooling.
The refrigerator does not work
on 120V AC
Refrigerator or freezer is not
cold enough
The refrigerator does not work in
gas operation mode
Odors from fumes
If the problem persists and the refrigerator is still not working properly, contact your nearest Service Center. State the problem,
model, product- and serial-number. (These details are stated on the data label inside the compartment.)
tRoUbLEShootiNg
check/Remedial action
•
Immediately turn the refrigerator off and see a Dometic dealer.
•
Defective fuse?
Fit a new fuse.
•
Connection to supply voltage?
Establish power connection.
•
Is the plug firmly connected to the socket? Is the socket switched on?
Check the socket by plugging in another appliance.
•
Is the thermostat properly set?
•
Is the refrigerator level? Because of its operation it is important to keep an
absorption refrigerator level.
•
Heavy frost build-up on evaporator fins? To prevent frost buildup, which can reduce
efficiency, do not leave the unit's door open longer than necessary.
•
Has the overheating protection been triggered or not? (Must be checked by an authorized
service technician.)
•
Is there a power failure? Are the fuses intact for the AC supply and control system?
•
Has the door been closed properly? If not it can cause the inside temperature to rise.
•
Overpacked refrigerator? The unit will have to work harder if the refrigerator is stuffed
and results in higher cabinet temperatures. Arrange the food in the unit to allow for free
air circulation.
•
Venting problem? Restriction in air flow across cooling unit? Ensure that there is suffi-
cient clearance between the refrigerator and the surrounding walls to allow for proper air
circulation around the unit.
NDA1402
•
Is the burner dirty, damaged or not properly located under the flue tube?
•
Is the burner jet clogged?
•
Is the flue baffle inserted properly in the flue tube?
•
Is the LP gas pressure low at burner?
Set the main regulator to regulate the pressure so it does not drop below 11 inches water
column at pressure tap.
•
Gas bottle empty? Change the gas bottle
•
Air in the gas pipe? Remove the air by switching the refrigerator on and off -4 times.
•
Dislocated burner
•
Damaged burner
•
Dirty flue tube
– 15 –