DO NOT operate the stove if the flame becomes dark and sooty or if the firepot overfills with pellets. Push
the OFF Touch Pad and inspect the heater. (See Operating Your Stove). Soot or creosote may accumu-
late in the exhaust vent system when the stove is operated under incorrect conditions such as an ex-
tremely rich burn. The flame will have a lazy orange color with black tips. This indicates poor pellet fuel
combustion.
NEVER block free airflow through the open vents of the unit. The viewing door and ash pan must be
closed and latched during operation.
The pellet appliance exhaust system works with negative combustion chamber pressure and a positive
chimney pressure, therefore the exhaust system must be completely airtight and properly installed. All ex-
haust system vent joints must be sealed, gas tight, with HI-TEMP RTV silicone sealant, and/or at least 3
sheet metal screws per joint and to the heater also.
Your heater requires periodic maintenance and cleaning (Refer to "Routine Cleaning" section of the
manual). Failure to maintain your heater may lead to smoke spillage in your home.
Disconnect the power cord from the electrical outlet before performing any maintenance. Pushing "OFF"
Touch Pad does not disconnect all power to the heater.
The exhaust system should be checked twice a year minimum for any build-up of soot or creosote. Do not
touch the hot surfaces of the heater.
NOTE: Hearth & Home Technologies grants no warranty, implied or stated, for the installation or
maintenance of your appliance, and assumes no responsibility of any consequential damage(s).
In accordance with the procedures and specifications listed in ASTM E 1509-04, and ULC-S627-00 for solid
fuel room heater, the Hearth & Home Technologies pellet stove has been independently tested and listed by
INTERTEK. (an accredited testing laboratory) to UL, ULC and CSA standards. It is tested and listed for resi-
dential installation according to current national and local building codes as:
A Freestanding Room Heater
A Hearth Stove
A Mobile Home Heater.
The Safety Listing Label is located on the rear
inspection panel for model CC1 and CC2.
Please read the label carefully.
It contains important information
about installation and operation of your
pellet appliance.
Note: Your STOVE'S serial number is located
on the safety label. Your appliance serial number
is preceded by a "007" (see diagram)
www.pelprostoves.com
CAUTION: Odors and vapors released during initial operation.
- Curing of high temperature paint.
- Open windows for air circulation.
Odors may be irritating to sensitive individuals.