Page 2
CHAUVET® to notify any person or company of such revision or changes. This does not constitute in any way a commitment by CHAUVET® to make such changes. CHAUVET® may issue a revision of this manual or a new edition of it to incorporate such changes.
Table of Contents Table of Contents 1. Before You Begin ....................1 What Is Included ......................... 1 Unpacking Instructions ......................1 Claims ............................1 Typographic Conventions ....................1 Icon Meaning ........................1 Product at a Glance ......................2 ...
Page 4
Table of Contents TOUR Notes ........................13 Master Dimmer .......................... 13 Red, Green, Blue White, and Amber Color Selection ............... 13 Color Macros ..........................13 Strobe ............................13 Auto/Custom ..........................13 Dimmer Speed ........................... 13 ...
CHAUVET®, upon receipt. Failure to do so in a timely manner may invalidate your claim with the carrier. In addition, keep the container and all the packing Claims material for inspection.
There are no user serviceable parts in this product. Any reference to servicing you find in this User Manual only applies to properly CHAUVET® certified technicians. Do not open the housing or attempt any repairs unless you are one of them.
Introduction 2. Introduction Product The COLORado™ Range IP is a RGBWA high intensity wash product used to light a variety of both indoor and outdoor applications. Consisting of a steel base and two Description adjustable panels, the base contains the power supply and the control unit. The panels attach to the steel arms that come from the base and are individually adjustable.
The listed current rating indicates the maximum current draw during normal operation. For more information, you may download the document Sizing the Circuit Breakers from the CHAUVET® website: www.chauvetpro.com. Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
If you are not familiar with the DMX standard, master/slave connectivity, or if you need information about the DMX cables needed to link this product to a DMX controller, you may download the document DMX Primer from the CHAUVET® website: www.chauvetpro.com. DO NOT connect a DMX controller to the unit’s operating in Master/Slave mode.
The COLORado™ Range IP consists of a heavy-duty rigid steel frame which enables this product to be hung overhead (using included omega brackets) or placed on the floor. CHAUVET® recommends following the general guidelines below when mounting this product. When selecting an installation location, consider ease of access to this product for operation, programming adjustments, and routine maintenance.
Operation 4. Operation Button Function Control Panel <MENU> Exits from the current menu or function Description Enables the currently displayed menu or <SET> sets the currently selected value in to the current function Navigates upward through the menu list and <UP>...
Operation DMX Control In this mode, each unit will respond to a unique starting address from the DMX controller. All units with the same starting address will respond in unison. 1. Select the personality as shown in DMX Personality. 2. Set the running mode: a.
Operation Master/Slave The Master/Slave mode enables a group of COLORado™ Range IPs (the slave units) to duplicate simultaneously the output of another COLORado™ Range IP (the master unit) without a DMX controller. 1. Set each of the slave units: 2. Go to RUN. 3.
Green indicates that the upload process completed successfully. Red indicates that the upload process failed due to an error. Recheck all cable connections and restart the process. If the issue persists, contact Chauvet Technical Support. DO NOT upload the data from a COLORado™ Range IP to a different product. The other product may be become inoperative.
Operation Reset This setting enables the user to reset the COLORado™ Range IP to the default values, including the custom programs. 1. Go to SET. 2. Select REST. 3. When PASS shows, press <SET>. 4. Enter the master access password as shown in Control Panel Lock. 5.
Operation TOUR Notes These notes clarify the way the TOUR DMX personality works. Channel 1 controls the intensity of the currently projected color. Master Dimmer When Channel 1 is at the highest position (100%) the intensity of the output is at its maximum.
Operation Menu Map Main Level Level Level Description GREN 000~255 User can combine Red, Green, Blue, White, and BLUE STAT (0~100%) Amber to generate a custom color. WHIT AMBE STRB 00~20 (0~20 Hz) Select a strobe frequency Choose from 10 automatic programs AUTO 1~10 Choose from 10 customizable programs...
Operation DMX Values TOUR Channel Function Value Percent/Setting 000 255 Dimmer 0~100% Module 1 Red 0~100% 000 255 Step Time Only when running custom programs Module 1 Green 0~100% 000 255 Step Time Only when running custom programs 000 ...
Technical Information 5. Technical Information Product To maintain optimum performance and minimize wear, the user should clean this product frequently. Usage and environment are contributing factors in determining the cleaning Maintenance frequency. As a rule, the user should clean this product at least twice a month. Dust build up reduces light output performance and can cause overheating.
Faulty Display/Main/DMX interface board Send unit for repair If you still experience technical problems after trying the above solutions or if you need to send the unit for repair, contact CHAUVET® Technical Support. -18- COLORado™ Range IP User Manual Rev. 06...
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be the customer’s responsibility. As a suggestion, proper FedEx packing or double boxing is the method Chauvet® recommends. CHAUVET® reserves the right to use its own discretion to repair or replace returned product(s). Contact Us World Headquarters United Kingdom &...
Technical Specifications Dimensions and Length Width Height Weight Weight 31.8 in (808mm) 10.0 in (252 mm) 22.0 in (560 mm) 89.0 lbs (40.3 kg) Note: Dimensions in inches rounded to the nearest decimal digit. Electrical Power Supply Type Range Voltage Selection Switching (internal) 100~240 V, 50/60 Hz Auto-ranging...