Figure i Model number designation External Telecommunication Nominal Btuhs (1000) 0=Standard Supply & Return Openings 3=4 or 5 Ton Unit With 3 Ton 7 = Scroll Compressor Supply & Return Openings with POE oil, R-407C R = Right Compressor L = Left Compressor P = 208/230V –...
Introduction NTRODUCTION General The Liebert InteleCool2 Environmental Control System was designed for convenience and dependability in unmanned and remote locations typical of the telecommunications industry. Ease of installation, operation and service coupled with the use of high quality, high reliability components make the Liebert InteleCool2 ideally suited for maintaining an environment for sensitive electronic equipment.
Introduction Optional Features 4 or 5 Ton Unit With 3 Ton Openings The 4- or 5-ton units with 3 ton supply and return openings are designed to replace 3 ton wall mounted air conditioners using existing wall openings. The economizer/fresh air option is not available.
Introduction 1.3.1 Refrigeration System Options Low Pressure Switch and Low Pressure Bypass Timer Low Pressure Switch: Used to protect the Liebert InteleCool2 if the evaporator blower fails, the air filter becomes clogged, the refrigeration circuit malfunctions or if there is loss of refrigerant. The low pressure switch is activated when the suction pressure drops below its cutout setting.
Upon delivery of the unit, inspect all items for visible damage. Concealed damage may be discovered later during installation. Report any damage to the shipper immediately and file a damage claim. Also, forward a copy of the damage claim to your Emerson supplier. Unit Installation The Liebert InteleCool2 unit is installed against, and through, an outside wall.
Installation Figure 1 Unit mounting dimensions 11" 11" 11" (279mm) (279mm) (279mm) See Table 1 below for keys to dimensions. M ref. Table 1 Mounting dimensional data Liebert InteleCool2 dimensional data in. (mm) Model 38-3/4 9-3/8 9-13/32 20-3/4 25-1/16 5-15/32 3-25/32 4-1/2 37-7/8...
Electrical connections to be made at the installation site are: line voltage power supply to the power input and control wiring to remote control (customer-supplied or Emerson option). DO NOT RUN CONTROL WIRING WITH HIGH VOLTAGE. 2.5.1...
Installation 2.5.2 Control Connections Control wiring will be required for the remote control device. This remote device may be a factory- or field-supplied wall thermostat or similar device. Connections to the unit are made using customary HVAC low volt wiring terminals R, G, W, and Y. For detailed locations of the low volt wiring terminals, please refer to the Figure 10 - Electric panels.
Installation Outside Air Damper—Optional Units supplied with fixed (non-modulating) outdoor air damper can be adjusted as follows: 1. Remove the screws from the middle panel and remove panel. 2. Loosen the damper plate screws on the backside of the middle panel. 3.
Checklist for Complete Installation HECKLIST FOR OMPLETE NSTALLATION ___ 1. Proper clearance for service access has been maintained. ___ 2. Equipment is level and mounting fasteners are tight. ___ 3. Ducting completed, if required. ___ 4. Line voltage to power wiring matches equipment nameplate. ___ 5.
8. Check adjustment of the optional outside air damper for the desired balance between the flow of room air and outdoor air. Use a gauge or non-polluting airflow indicator. NOTE If the unit is supplied with crankcase heaters, Emerson recommends that the high voltage be applied between four and six hours before startup.
Operation PERATION Compressorized Cooling Compressorized cooling is provided by a high efficiency system consisting of a compressor, thermostatic expansion valve, evaporator, and condenser coil. The Liebert InteleCool2 uses R-407C refrigerant in a conventional vapor-compression refrigeration cycle. Heat is removed from the air in the space by blowing the air across the evaporator coil. As heat is transferred to the refrigerant in the evaporator, the refrigerant boils and turns to a warm vapor.
Operation Economizer Cooling—Optional The Economizer mode uses outside air to cool the room when the outside air temperature is cool enough to allow for economical cooling. Components include the damper, spring return direct drive actuator, enthalpy sensor and actuator control board with an integral mixed air sensor. Economizer operation is enabled when the outside conditions meet required temperature and humidity as set on the enthalpy sensor.
Operation Unit Controls 5.4.1 Remote Control Interface Control connections to the Liebert InteleCool2 unit use customary HVAC terminal designations R, G, W & Y. Contact closures between the 24 VAC (R) and different control connections supply control voltage to the electric panel components responsible for the desired function. Operating modes are controlled by contact closures as follows: Table 2 Operating modes/contact closures...
Operation T-pack1 package Includes a low pressure switch, low pressure bypass timer (described above) and fan cycle control. Fan Cycle Control—Condenser Fan Cycling Control; allows the Liebert InteleCool2 unit to provide cooling to the space when the outdoor ambient temperature is lower than 50°F (10°C) and down to -20°F (-28.9°C).
Maintenance AINTENANCE WARNING Risk of electric shock. Can cause injury and death. Disconnect all local and remote electric power supplies before working within. Potentially lethal voltages exist within this equipment during operation. Observe all cautions and warnings in this manual. Only qualified service and maintenance personnel should work with this equipment.
Maintenance 6.5.1 Refrigerant Lines Check all refrigerant lines and capillaries for vibration isolation, and support as necessary. Visually inspect all refrigerant lines for leaks. 6.5.2 Discharge Pressure Discharge pressure can be increased or decreased by load conditions or condenser efficiency. The high-pressure switch will shut the compressor/contactor at its cut-out setting of 400 PSIG (2758 kPa).
Page 23
Maintenance Mechanical Failure A mechanical compressor failure will not be indicated by a burned odor. The motor will attempt to run. If you have determined that a mechanical failure has occurred, the compressor must be replaced. Electrical Failure An electrical failure will be indicated by a distinct pungent odor. If a severe burnout has occurred, the oil will be black and acidic.
6.6.1 Compressor Replacement Replacement compressors are available from your Emerson supplier. They will be shipped in a reusable crate to the job site as required by the service contractor. Upon shipping a replacement compressor, the service contractor will be billed in full for the compressor until the failed compressor has been returned to the factory.
Specifications PECIFICATIONS Dimensional Data Figure 6 Dimensional data 2-1/4" (58mm) Entrance for high volt connections 4" (102mm) supply 1-11/16" (43mm) Entrance for low volt connections return Shaded areas indicate a recommended clearance of 34" (864mm) in front and 30" (762mm) each side, or 36"...
Specifications Table 7 Technical data, 60 Hz - Standard ambient condenser, continued Model ET048, ET348 ET060, ET360 Compressor Type Scroll Scroll Net capacity data based on 80°F (26.6°C) DB/67°F (19.4°C) WB indoor ambient - BTUH (kW)* Outdoor ambient Total 47900 (14.0) 56900 (16.7) 85°F (29.4°C)
Specifications Table 8 Technical data, 50 Hz - Standard ambient condenser Model ET035 Compressor type Scroll Net capacity data based on 26.6°C (80°F) DB/19.4°C (67°F) WB indoor ambient - kW (BTUH)* Outdoor ambient 29.4°C Total 8.3 (28200) (85°F) Sensible 6.2 (21300) 35.0°C Total 7.8 (26600)
Specifications Table 9 Technical data, 50 Hz - Standard ambient condenser, continued Model ET047, ET347 ET059, ET359 Compressor type Scroll Scroll Net capacity data based on 26.6°C (80°F) DB/19.4°C (67°F) WB indoor ambient - kW (BTUH)* Outdoor ambient Total 11.8 (40400) 14.2 (48500) 29.4°C (85°F)
Specifications Table 11 Technical data, 60 Hz - High ambient condenser, continued Model ET048, ET348 ET060, ET360 Compressor Type Scroll Scroll Net capacity data based on 80°F (26.6°C) DB/67°F (19.4°C) WB indoor ambient - BTUH (kW)* Outdoor ambient Total 49200 (14.4) 59000 (17.3) 85°F (29.4°C)
Specifications Table 12 Technical data, 50 Hz - High ambient condenser Model ET035 Compressor type Scroll Net capacity data based on 26.6°C (80°F) DB/19.4°C (67°F) WB indoor ambient - kW (BTUH)* Outdoor ambient 29.4°C Total 8.6 (29200) (85°F) Sensible 6.3 (21600) 35.0°C Total 8.1 (27700)
Specifications Table 13 Technical data, 50 Hz - High ambient condenser, continued Model ET047, ET347 ET059, ET359 Compressor type Scroll Scroll Net capacity data based on 26.6°C (80°F) DB/19.4°C (67°F) WB indoor ambient - kW (BTUH)* Outdoor ambient Total 12.1 (41400) 14.6 (50000) 29.4°C (85°F)
Troubleshooting ROUBLESHOOTING Table 18 Troubleshooting guide Problem Probable Cause Remedy No power to unit Check voltage to input circuit breaker. Control voltage circuit Locate short and reset breaker. breaker open Unit will not start Shut off by external thermostat or stat is Check operation of thermostat.
Parts 10.0 P ARTS Table 19 Refrigeration system parts, 1.5 and 2 ton units 1.5 Ton 2 Ton ET017S ET018P ET023S ET023M ET024P ET024Y ET024A Figure Part Name/ 220-240V 208-230V 220-240V 380-415V 208-230V 208-230V 460V Description Part # 1 Ph 50 Hz 1 Ph 60 Hz 1 Ph 50 Hz 3 Ph 50 Hz...