9. Troubleshooting

Always turn off the mains supply to AC alarms before checking connections etc..
Symptom
1. Green L.E.D. not lit
2. Frequent nuisance
alarms
3. Alarm chirps every 40
seconds
4. Alarm does not sound
when test button
pressed and held.
5. Interconnected alarms
do not sound when test
button is pressed and
held.

10. Useful Hints

Smoke/heat alarms can only operate correctly if smoke particles/heat reach the
unit. Correct selection/siting and installation are covered in the installers manual, who
fitted your alarm/s.
Building Regulations require new homes to have 1 hard wired smoke alarm per floor
and to be interlinked. From 2000 they will additionally require an interlinked heat alarm
to be fitted in most kitchens too. i.e. 3 alarms per property.
With the exception of garages/kitchens/bathrooms it is recommended that smoke
alarms are fitted in every room and outside all sleeping areas too.
A professional electrician should be employed for all mains powered (hard wired)
alarms.
If you are redecorating your home, paint fumes can contaminate the alarm – tem-
porarily cover the unit with a plastic bag (during this time the alarm will not function).
Never paint the alarm.
Only remove the bag when the paint is thoroughly dry.
If you extend your property, review your alarm requirements.
Smoke/heat alarms should be replaced every 10 years or sooner.
These products are designed for domestically scaled premises.
6:05 PM
Page 9
Possible cause/solutions
a. Loss of mains power – check at Consumer Unit for
Blown Fuse or tripped Circuit Breaker.
b. Check cables at back of alarm, are correctly seated
/ wired in and the alarm is pushed fully home (see
"Battery Changing" section).
See sections 2,3,4 and 7. If sited incorrectly/not
regularly cleaned as section 11, nuisance alarms can
occur.
See section 5 (if the hush button has been pressed
the unit will chirp for 7 minutes to indicate it is in hush
mode).
See parts 1a and 1b above. Have installer re check
wiring if Green LED is illuminated, but alarm does not
appear to function. If no Green LED check consumer
unit. Alarm with still function on battery power, if bat-
tery is in serviceable state. <Red LED will blink about
once a minute to confirm>. Check via Test Button.
See part 1b above – consult a qualified electrician or
your Landlord to remedy as soon as possible.