To use the ice maker after seasonal storage:
!
CAUTION:
Do not operate the ice maker when the ambient air temperature is 0° F. or lower. Damage to the water solenoid
valve and the water supply line can occur.
1. Remove the tape and plastic bags from the end of the water supply line, the end of the ice maker water line, and the water solenoid
valve.
2. Connect the ice maker water line to the water solenoid valve.
3. Connect the garden hose adapter to the water solenoid valve.
4. Push the ice maker arm down into the ON position.
5. Open the vehicle water supply valve to the ice maker.
NOTE: You should discard and not use the first two batches of ice cubes. It will take about three cycles for the ice maker to make fully
formed and clean ice cubes.

Refrigerator Maintenance

Gas flame appearance:

While in LP GAS operation, examine the appearance of the gas flame:
- Push the TEMP SET button until the number "9" appears in the center display.
- Open the lower intake vent.
!
CAUTION:
The burner box cover can be hot. Wear gloves to avoid burns.
- Look at the gas flame [75] (See Art00955).
- The flame should be:
- a darker blue color on the inside of the flame and a lighter blue color on the
outside of the flame.
- a constant shape without flickering.
- Contact your dealer or Norcold authorized service center if the flame is:
- yellow
- flickering or changing shape.
- Make sure the flame does not touch the inside of the flue tube [76].
- If the flame touches the inside of the flue tube, contact your dealer or Norcold authorized service center.
- Close the burner box door.