Circuit Diagram - Creda NewEra 79348S Assembly Instruction Manual

Tsr supaslim combi combined storage and fan heater
Hide thumbs Also See for NewEra 79348S:

Advertisement

ENSURE THAT THE CABLES ARE NOT TRAPPED
UNDER THE HEATER LEGS
ENSURE THAT CABLE
CLAMP IS SECURELY
ATTACHED TO THE
CHASSIS OF THE HEATER.
Storage Heater Circuit
75772001S
Combi Fan Heater Circuit
RESTRICTED
SUPPLY
UNRESTRICTED
SUPPLY
79348S
RESTRICTED
SUPPLY
6
MAINS TERMINALS
IMPORTANT: For earthing, loosen the earth screws
sufficiently to wrap the mains' earth wire around it between
flat washer and cup washer, and retighten the earthing
screw. Both restricted and unrestricted supply wires must be
connected to their respective earthing points.
Feed the mains cable through the appropriate cable clamp
and make connections as marked on the heater. Pull back
any slack through the clamp and tighten clamping screw.
Make sure clamp is tightening on outer sheath of cable and
not on individual conductors. If mains connection is to be
made from the left hand side, at this point the mains lead
must be secured to the base of the fan box by fixing the
ties provided in the fixing kit through the holes along the
rear of the fan box base.
CONNECTING
THE SUPPLIES
79348S
& 75772001S
NOTE:
factory set at full rating. If ½ load rating
only is required the installer should
move the black wire as indicated in the

circuit diagram.

Charge
Period
7 hours
The fan heater element is
Rated
Charge
12 kWh