Dust Collection

DO NOT operate the Model G0690 or G0691
without an adequate dust collection system.
This saw creates substantial amounts of
wood dust while operating. Failure to use a
dust collection system can result in short
and long-term respiratory illness.
Components and hardware Needed:
dust hose 4 " (not included) ...............................1
hose Clamps 4" (not included) ..........................2
dust Collection system (not included) ...............1
Recommended CFM at Dust port: 400 CFM
Do not confuse this CFM recommendation with
the rating of the dust collector. To determine the
CFM at the dust port, you must consider these
variables: (1) CFM rating of the dust collector,
(2) hose type and length between the dust col-
lector and the machine, (3) number of branches
or wyes, and (4) amount of other open lines
throughout the system. Explaining how to cal-
culate these variables is beyond the scope of
this manual. Consult an expert or purchase a
good dust collection "how-to" book.
To connect a dust collection hose:
1.
Fit a 4" dust hose over the dust port, as
shown in Figure 36, and tightly secure in
place with a hose clamp.
2.
tug the hose to make sure it does not come
off. Note: A tight fit is necessary for proper
performance.
Figure 36. dust hose attached to dust port.
-30-

power Connection

After you have completed all previous setup
instructions and circuit requirements, the machine
is ready to be connected to the power supply.
To avoid unexpected startups or property dam-
age, use the following steps whenever connecting
or disconnecting the machine.
Connecting power
1. Turn the machine power switch OFF.
Qty
2. Insert the power cord plug into a matching
power supply receptacle. The machine is
now connected to the power source.
Figure 37. Connecting power.
Disconnecting power
1. Turn the machine power switch OFF.
2. Grasp the molded plug and pull it completely
out of the receptacle. Do not pull by the cord
as this may damage the wires inside.
Figure 38. Disconnecting power.