Graco 235-459 Instructions-Parts List Manual page 10

Flex airless spray gun c series; b series; d series
Table of Contents

Advertisement

7. Slide the rear of the needle (2c*) into the front of
the gun. Slide the tool (B), provided with the repair
kit, into the gun, around the needle. Lightly tap the
tool with a hammer or lightly press the tool against
a flat surface to seat the needle. See Fig. 9.
Remove the tool.
CAUTION
Tapping or pressing the tool too hard may jam the
tool and damage the needle.
Fig. 9
Service
8. Grease the end of the needle.
9. Grease the diffuser/seat threads. Place the new
10. Install the trigger (8), pivot pin (11) and screw (12).
NOTE: No needle or trigger adjustment is needed.
B
2c
02351
gasket (2b*) on the diffuser/seat (2a*) and screw
the assembly into the fluid housing (7). Torque to
20–25 ft-lb (27–34 N.m). See Fig. 6.
See Fig. 6.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents