1000Base-T Pin Assignments; 1000Base-T Mdi And Mdi-X Port Pinouts - Alcatel OMNISTACK LS 6200 Getting Started Manual

Ethernet based switch
Table of Contents

Advertisement

B
Cables
Table B-1. 10/100BASE-TX MDI and MDI-X Port Pinouts
Pin
1
2
3
6
4,5,7,8
Note: The "+" and "-" signs represent the polarity of the wires that make
up each wire pair.

1000BASE-T Pin Assignments

All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use
straight-through cables for all network connections to PCs or servers, or to other
switches or hubs.
The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports
require that all four pairs of wires be connected. Note that for 1000BASE-T
operation, all four pairs of wires are used for both transmit and receive.
Use 100-ohm Category 5, 5e or 6 unshielded twisted-pair (UTP) or shielded
twisted-pair (STP) cable for 1000BASE-T connections. Also be sure that the length
of any twisted-pair connection does not exceed 100 meters (328 feet).
Table B-2. 1000BASE-T MDI and MDI-X Port Pinouts
Pin
MDI Signal Name
1
Bi-directional Data One Plus (BI_D1+)
2
Bi-directional Data One Minus (BI_D1-)
3
Bi-directional Data Two Plus (BI_D2+)
4
Bi-directional Data Three Plus (BI_D3+)
5
Bi-directional Data Three Minus (BI_D3-)
6
Bi-directional Data Two Minus (BI_D2-)
7
Bi-directional Data One Plus (BI_D4+)
8
Bi-directional Data Four Minus (BI_D4-)
Cable Testing for Existing Category 5 Cable
Installed Category 5 cabling must pass tests for Attenuation, Near-End Crosstalk
(NEXT), and Far-End Crosstalk (FEXT). This cable testing information is specified in
the ANSI/TIA/EIA-TSB-67 standard. Additionally, cables must also pass test
parameters for Return Loss and Equal-Level Far-End Crosstalk (ELFEXT). These
B-26
MDI-X Signal Name
Receive Data plus (RD+)
Receive Data minus (RD-)
Transmit Data plus (TD+)
Transmit Data minus (TD-)
Not used

1000BASE-T MDI and MDI-X Port Pinouts

MDI Signal Name
Transmit Data plus (TD+)
Transmit Data minus (TD-)
Receive Data plus (RD+)
Receive Data minus (RD-)
Not used
MDI-X Signal Name
Bi-directional Data Two Plus (BI_D2+)
Bi-directional Data Two Minus (BI_D2-)
Bi-directional Data One Plus (BI_D1+)
Bi-directional Data Four Plus (BI_D4+)
Bi-directional Data Four Minus (BI_D4-)
Bi-directional Data One Minus (BI_D1-)
Bi-directional Data One Plus (BI_D3+)
Bi-directional Data Three Minus (BI_D3-)

Hide quick links: