Instructions For The Installer - Electrolux EOB 53011 User Instructions

Electrolux built-in oven
Table of Contents

Advertisement

Available languages

Available languages

72 electrolux

Instructions for the Installer

Installation and connection
must be done in compliance
with the regulations in force.
Any interventions must be
carried out when the appliance
is
switched
accredited engineers may work
on the appliance.
The manufacturer disclaims
any liability if the safety
measures are not observed.
Connecting to the electrical supply
Before connecting to the electrical
supply, please make sure:
- The fuse and the domestic electrical
installation must be designed for the
max. load of the appliance (see rating
plate).
- The domestic electrical installation
must be equipped with a proper earth
connection in accordance with the
regulations in force.
- The socket or the multi-pole off switch
must be easy to access after the
appliance has been installed.
This appliance is delivered with an elec-
tric supply cable.
A proper plug, according to the elec-
tric load specified on the rating plate,
must be fitted to the cable. The plug is
to be inserted into a suitable wall socket.
If you require a direct connection to the
electric network (mains), it will be nec-
essary to fit between the appliance and
the mains an omnipole switch, with a
minimum gap between contacts of 3
mm, suitable for the required load and in
compliance with rules in force. The green
& yellow ground wire must not be inter-
rupted by the switch and it should be 2-
3 cm. longer than the other cables.
plied are to be connected to a shock-
proof socket (230 V~, 50 Hz). The shock-
proof socket must be installed in accor-
dance with the regulations.
off.
Only
are suitable, taking the necessary rated
cross section into account: H07 RN-F,
H05 RN-F, H05 RR-F, H05 VV-F, H05
V2V2-F (T90), H05 BB-F.
case be laid out so that at no point does
it reach 50°C (over room temperature).
out, the heating elements must be tested
by being operated for about 3 minutes.
Terminal block
The oven is fitted with an easily accessible
terminal block which is designed to
operate with a single-phase power
supply of 230 V.
Letter L
Letter N
The mains cable and plug as sup-
The following types of mains cable
The connection cable must in any
After the connection has been carried
-
Live terminal
-
Neutral terminal
or E - Earth terminal

Advertisement

Chapters

Table of Contents
loading

Table of Contents