If installation beside a heat source is unavoidable,
the following minimum distances at the sides are to
be complied with: To electric cookers 3 cm, to oil or
coal fired cookers 30 cm.
Install a heat protection panel between the two
appliances.
The appliance should be installed on a firm, hori-
zontal surface. Correct any floor irregularities by
twisting the adjustable feet in or out.
Adjustable feet - working
height 85/86 cm
Fig. 1
Your appliance is fitted with 4 adjustable feet as
standard, with which you can compensate for any
floor irregularities by turning them inwards or
outwards. If the appliance is to be fitted underneath
a continuous worktop, the four adjustable feet must
be screwed into the low-lying position (A).
Special accessory -
adjustable feet for 90/91 cm
working height
Fig. 2
If the appliance is to be set up for a working height
of 90/91cm, 4 adjustable feet (B) should be orderd
and screwed in which are 6 cm long (E-No. 621
833 004) The standard feet can be kept in place,
screwed into the low-lying position (A).

Electrical connection

WARNING - THIS APPLIANCE MUST BE
EARTHED
Please ensure that the voltage and current indicated
on the rating plate agree with the voltage of your
electricity supply.
220/240 volts (i. e. 220/240 V AC).
If your appliance has been equipped with a mains
lead with a moulded-on type plug, you must comply
with the following regulations: The plug moulded on
to the cord incorporates a fuse. For replacement,
use a 13 amp BS 1362 fuse. Only ASTA approved
or certified fuses should be used. The fuse cover/
carrier must be replaced in the event of changing
the fuse. The plug must not be used if the fuse
cover/carrier is lost. A replacement cover/carrier
must be obtained from an electrical goods retailer. If
the socket outlets in your home are not suitable for
the plug fitted to the appliance, then the plug must
be cut off and an appropriate one fitted. When
fitting the plug please note the following points:
Important
The wires in the mains lead are coloured in accord-
ance with the following code:
Green and Yellow
Blue
Brown
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
1. The wire which is coloured green and yellow
must be connected to the earth terminal in your
plug, which is marked with the letter E or by the
earth symbol
and yellow,
2. The wire which is coloured brown must be con-
nected to the live terminal which is marked with
the letter L or coloured red.
3. The wire which is coloured blue must be con-
nected to the neutral terminal which is marked
with the letter N or coloured black.
When wiring the plug, ensure that all strands of wire
are securely retained in each terminal. Do not forget
to tighten the mains lead clamp on the plug.
Warning! A cut-off plug inserted into a 13 amp
socket is a serious safety (shock) hazard. Ensure
that the cut-off plug is disposed of safely
Voltage
220/240 V AC
Fuse rating
13 amps
See rating plate for further information.
The rating plate is located on the inside of the appli-
ance.

Plug socket

Fig. 3
The plug socket necessary for connection of the
freezer to the electricity supply should be positioned
so that it is possible to pull out the appliance
plug.
If the appliance is installed under a continuous
worktop, the plug socket should be provided as in
Fig. 3 . A concealed protective plug socket requires
a 10 A/16 A fuse.
Earth
Neutral
Live
or coloured green, or green