Goodman UPFLOW/HORIZONTAL GME8 Technical Manual page 5

Gme8 series 33-3/8" 80% gas furnace upflow/horizontal
Hide thumbs Also See for UPFLOW/HORIZONTAL GME8:
Table of Contents

Advertisement

PRODUCT DESIGN
Accessibility Clearances (Minimum)
Unobstructed front clearanace of 24" for servicing is rec-
ommended.
Top clearance for horizontal confirguration - 1"
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS - INCHES
Sides
Rear
Front
1
0
3
Approved for line contact in the horizontal postion.
* 24" clearance for serviceability recommended.
** Single Wall Vent (SW) to be used only as a connector.
Refer to venting tables outlined in the installation manual for
additional venting requirements.
24" at front is required for servicing or cleaning.
Note: In all cases accessibility clearance shall take prece-
dence over clearances from the enclosure where accessibil-
ity clearances are greater. All dimensions are given in inches.
Vent
Bottom
Top
SW
B
C
6
1
High Altitude Derate
When this furnace is installed at high altitude, the appropri-
ate High Altitude orifice kit must be installed. This is re-
quired due to the natural reduction in the density of both the
gas fuel and combustion air as altitude increases. The kit
will provide the proper design certified input rate within the
specified altitude range.
INPUT PER BURNER - 22,500 BTUH NATURAL GAS / 20,000 BTUH L.P.
1
2000
US BURNER
44/55
ORIFICE
CANADA BURNER
44/55
ORIFICE
HA-02 HIGH ALTITUDE CONVERSION KIT REQUIRED
Tabled data is based upon the furnace input being reduced for altitudes above sea level. U.S. 4% per 1,000 feet.
Canada 10% derate for 2,000-4,000 feet.
High altitude kits are purchased according to the installa-
tion altitude and usage of either natural or propane gas. Refer
to the chart above for a tabular listing of appropriate altitude
ranges and corresponding manufacturer's high altitude Natu-
ral Gas and Propane Gas kits. For a tabular listing of appro-
priate altitude ranges and corresponding manufacturer's High
Altitude Pressure Switch kits, refer to either the Pressure
Switch Trip Points & Usage Chart in this manual or the Ac-
cessory Charts in Service Instructions.
ELEVATION ABOVE SEA-LEVEL (FEET)
3000
4000
4500
5000
6000
44/55
45/56
45/56
46/57
47/57
7000
8000
47/58
47/58