Page 3
To reset the indicators use the channel up/down buttons on the ESTIME 3000 SC or the ‘all up’ or ‘all down’ buttons on the ESTIME 3000 AMF until normal operation is obtained.
Page 5
To reset the indicators use the channel up/down buttons on the ESTIME 3000 SC or the ‘all up’ or ‘all down’ buttons on the ESTIME 3000 AMF until normal operation is obtained.
ESTIME 3000 AMF model only - Selectable flash output from one single flash head from full power of 3000 Watt seconds using socket number 1 reducing in 1/3rd ‘f’...
3000 SC. To make use of either of these features requires the purchase of accessories which are obtainable separately:- A special socket enables the ESTIME 3000 AMF to be powered from a 12 volt car battery via the Switched Mode Module accessory (Part Number BW-2906).
Flash Head distance. A study of the following diagrams will explain all possible combinations of flash heads. Diagrams 1 to 9 are for the ESTIME 3000 AMF and Diagrams 10 to 18 are for the ESTIME 3000 SC. - 8 -...
Page 9
3000 AMF WITH ONE FLASH HEAD IN N0.1 SOCKET a) Socket 1 power indication illuminated. b) Socket 1 Up-Down buttons control power selection. c) Full output of 3000 Watt seconds available In Use reducing in 1/3rd ‘f’ stop steps over 3 ‘f’ stops to 1/8th power.
Page 10
3000 AMF WITH TWO FLASH HEADS IN N0S. 1 & 2 SOCKETS a) Socket 1 power indication only. b) Socket 1 Up-Down buttons control power to BOTH sockets 1 &2. c) Full output of 1500+1500 Watt seconds available from In Use In Use sockets 1 &2.
Page 11
3000 AMF WITH THREE FLASH HEADS IN N0S.1,2 & 3 SOCKETS a) Socket 1,2 & 3 power indication illuminated. b) Sections 1,2 & 3 Up-Down buttons control their own sections separately. c) Full output of 1000 Watt seconds available from In Use In Use In Use...
Page 12
3000 SC WITH ONE FLASH HEAD IN N0.1 SOCKET a) Power indication illuminated. b) Up-Down buttons control power selection. c) Full output of 3000 Watt seconds available reducing in 1/3rd ‘f’ stop steps over 3 ‘f’ stops to In Use 1/8th power.
Page 13
3000 SC WITH TWO FLASH HEADS IN N0S. 1 & 2 SOCKETS a) Power indication illuminated. b) Up-Down buttons control power to BOTH sockets 1 &2. c) Full output of 1500+1500 Watt seconds available from sockets 1 &2. In Use In Use d) Power from both sockets 1 &...
Page 14
3000 SC WITH THREE FLASH HEADS IN N0S.1,2 & 3 SOCKETS a) Power indication illuminated. b) Up-Down buttons control power to ALL three sockets. c) Full output of 1000 Watt seconds available from In Use In Use In Use each flash head reducing in 1/3rd ‘f’ stop steps over 3 ‘f’...
‘Photocell’ push button (13) is illuminated the sounder is switched ‘ON’. Press the ‘Photocell’ push button to toggle between Photocell ‘ON’ and ‘OFF’. Three ‘Sync.’ sockets are provided on the control panel of the ESTIME 3000 AMF and two on the ESTIME 3000 SC. One standard European 6.5mm jack socket and one three blade socket as used in the U.S.A.
Using this socket with the supplied special AMF sync. lead the generator will flash as soon as it comes to ‘READY’ for as long as the socket contacts are held closed. The ‘B’ shutter setting of most mechanical and electronic cameras will provide this function.
12. Battery Supply (27) FIG 4 The ESTIME 3000 AMF may be powered from a 12 volt car battery via the Switch Mode Power Supply Module accessory, (BW-2906). No modelling is available when this is used. IMPORTANT: THE SWITCHED MODE POWER SUPPLY MODULE MUST NEVER BE CONNECTED AT THE SAME TIME AS THE MAINS SUPPLY.
NOTE: THE CAR ENGINE MAY BE RUN TO RECHARGE THE BATTERY, WHILE THE SWITCHED MODE POWER SUPPLY IS CONNECTED, AS REQUIRED. 13. Remote Control - ESTIME 3000 AMF ONLY The ESTIME 3000 AMF has a built in infrared remote control receiver.
Page 19
RATIO MODELLING the remote control transmitter the OUTPUTS 1 + 2 + 3 Generator Photocell must first be BOWENS switched ‘ON’. This can, of course, TRAVELLER G REMOTE CONTROL be set from the remote control. M a d e i n...
14. Safety Summary ESTIME 3000 generators must only be used on an AC (Alternating Current) mains supply. Never connect to a DC (Direct Current) supply (except when using the Switch Mode Power Supply module via its dedicated supply socket). Never attempt to use any other type of Switch Mode Power Supply.
3KGH Head Full power into 1 x 1/429 1/429 3KGH Head 1000 Watt sec. into 1/1100 1/1100 1 x 3KGH Head NOTE: THE ESTIME 3000 AMF AND 3000 SC ARE FULLY COMPATIBLE WITH ALL TRAVELLER G FLASH HEADS. - 21 -...
Page 22
Ten types of flash heads are currently available for use with ESTIME 3000 Generators. All listed flash heads, except the Linear head, use the standard ‘S’...
Page 23
Plus full range of Stands, Umbrellas, Reflectors and Register Wafers. For details of all related products, please contact your nearest Bowens dealer. Due to our policy of constant product improvement Bowens International Limited reserve the right to change equipment specifications without notice.
Page 24
ESTIME 3000 INSTRUCTIONS BWL-0173/2 16-8-94 BOWENS INTERNATIONAL LIMITED a PROMANDIS group company 355 OLD ROAD CLACTON-ON-SEA ESSEX CO15 3RH ENGLAND Tel: +44(0)1255 422807 Fax: +44(0)1255 436342 - 24 -...