AOpen H800 User Manual
AOpen H800 User Manual

AOpen H800 User Manual

Server chassis

Advertisement

1
Introduction
Copyright
Copyright © 2000 by AOpen Inc. All rights reserved.
No part of this document may be copied or reproduced in any form or by any means without
the prior written consent of AOpen Inc.
AOpen makes no warranties with respect to this documentation and disclaims any implied
warranties of merchantability, quality, or fitness for any particular purpose. The information
in this document is subject to change without notice. AOpen reserves the right to make
revisions to this publication without obligation to notify any person or entity of any such
changes.
®
AOpen
is a registered trademark of AOpen Inc. Other trademarks or brand names mentioned herein
are trademarks or registered trademarks of their respective owners.

Advertisement

Table of Contents
loading

Summary of Contents for AOpen H800

  • Page 1 The information in this document is subject to change without notice. AOpen reserves the right to make revisions to this publication without obligation to notify any person or entity of any such changes.
  • Page 2: Table Of Contents

    Table of Contents Introduction................1-1 1.1. Configuration ..................1-2 1.2. Features .................... 1-3 Parts Description..............2-1 2.1. Front Cover and Front Panel ............. 2-2 2.1.1. Front Cover ................2-2 2.1.2. Front panel ................2-3 2.2. Back Panel ..................2-4 2.2.1. Power Supply ................. 2-4 2.2.2.
  • Page 3: Introduction

    Introduction Introduction The H800 is a user-friendly server chassis that has been tested and found to be complied with the restrictions for a Class B device of the FCC Rules, CE, C tick and all EMC requirements. Any accessing, upgrading and maintenance operation to the system can be easily performed and done.
  • Page 4: Configuration

    Support one I/O port bracket for standard ATX M.B. Support 1 FDD with FDD cable Long card Guide Support 2 sets of long card guide Optional Hand set & Wheel Rack mount accessory kit BPL6: support 6 pcs Hot swap SCSI HDD H800 Server Chassis...
  • Page 5: Features

    Introduction 1.2. Features User’s Guide...
  • Page 6 Disk drive bay installed by screw or slide guide 10pcs slide guides for the installation of 5.25” devices (including HDD cage) Optional wheel and hand set makes it incredibly mobile One built-in 8 cm fan (one more optional 8cm fan available) H800 Server Chassis...
  • Page 7: Parts Description

    Parts Description Parts Description The H800 is designed to maximize the extension ability of the system for you to access, upgrade, and maintain it. The H800 is consist of: Front Cover and Front Panel Back Panel Main Body Cooling System...
  • Page 8: Front Cover And Front Panel

    2.1. Front Cover and Front Panel The H800 is designed with a key lock on the door to protect against inadvertent access to the power button, reset button, and disk drives. Behind the door are mountings for nine 5.25” and one 3.5” drive bays, one Power button, one Reset button, one Intrusion Alarm Detector, and three LED indicators.
  • Page 9: Front Panel

    Parts Description 2.1.2 Front panel Drive Bays: The H800 is designed with nine 5.25” drive bays and one 3.5” drive bays. You can occupy the space of two 5.25” drive bays 3.5-inch Drive Bays with one standard HDD cage; and the space of HDD cage can be occupied with three 3.5”...
  • Page 10: Back Panel

    Parts Description 2.2. Back Panel There are four components available to be installed on the back panel of H800: (1) Power Supply, (2) I/O Ports, (3) Expansion Slots, and (4) Housing Fans. 2.2.1 Power Supply The H800 provides 2 solutions: 1.
  • Page 11: I/O Ports

    2.2.4. Housing Fans The H800 has a built-in 8cm FAN and one optional 8cm FAN on its back panel. Besides, it reserves another space for one 8cm FAN on the front panel, which can be placed together with HDD cage.
  • Page 12: Main Body

    Parts Description 2.3. Main Body The H800 provides a strong structure and impediment-free design for easy assembly. 9x5.25” drive Sliding in or screwing for components assembly Long Card Guide x2 pcs MB size: supports up to 12x13” MB with Pentium4 CPU mounting holes MB type: SSI, Full ATX, AT &...
  • Page 13: Cooling System

    2.4. Cooling System The H800 is equipped with one 8cm fan at the rear panel, and is also possible to add one more optional 8cm fan to make it a two-fan cooling system. There is one more optional way of adding another 8cm fan to the 3.5” HDD cage located at front panel.
  • Page 14: Security Device

    2.5. Security Device The H800 has one mechanical key lock on the front panel cover and one electrical chassis intrusion alarm to prevent unauthorized access to components inside the chassis. The chassis intrusion alarm is an electrical detecting device that came with the motherboard.
  • Page 15: Power Supplies

    Parts Description 2.6. Power Supplies The H800 supports standard ATX 12V and redundant 337W (with or without 2 power) power supplies. 2.6.1 Standard ATX 12V power supply Before Assembly standard ATX 12V power supply, it must assemble power bracket with power than can install to chassis.
  • Page 16 0.1 uF monolithic ceramic capacitor paralleled by a 10 uF electrolytic capacitor across the measuring terminals. REGULATORY COMPLIANCE SAFETY REQUIREMENTS -CSA C22.2 -UL 1950 -IEC 950 -TUV EN 60950 -NEMKO + CB REPORT DIELECTRIC STRENGTH -Primary to Frame Ground : 1800 Vac for 1 sec. H800 Server Chassis...
  • Page 17 2-11 Parts Description -Primary to Secondary : 1800 Vac for 1 sec. INSULATION RESISTANCE -Primary to Secondary : 20 Meg. ohms Minimum. -Primary to FRAME GROUND : 20 Meg. ohms Minimum. GROUND LEAKAGE CURRENT -The power supply ground leakage current shall be less than 3.5mA. EMISSION REQUIREMENTS -When testing the power supply must operate within the listed requirements.
  • Page 18 -Primary to Secondary : 1800 Vac for 1 sec. INSULATION RESISTANCE -Primary to Secondary : 20 Meg. ohms Minimum. -Primary to FRAME GROUND : 20 Meg. ohms Minimum. GROUND LEAKAGE CURRENT The power supply ground leakage current shall be less than 3.5mA. EMISSION REQUIREMENTS H800 Server Chassis...
  • Page 19: Redundant 337W Power Supply

    2-13 Parts Description When testing the power supply must operate within the listed requirements. OTHER REQUIREMENTS COOLING With the fan voltage set to around 12 volts, the fan will deliver greater than 38 CFM with the power supply in open air. INPUT CONNECTIONS Refer to Mechanical Specifications for placement.
  • Page 20 (4) Inrush current of this module shall not exceed 60 amperes peak at 100 vrms input voltage, the inrush current measured at cold start. (5) Efficiency: 63% min. At low line 110/220 VAC (60Hz) full load. (6) Power Factor Correction : the power module (RPS-600A compatible with H800 Server Chassis...
  • Page 21 2-15 Parts Description DPS-300AB-1) shall meet the IEC-1000-3-2 Standard. (7) Electrical performance should compatible with RPS-600A. Static Output Characteristics: LOAD OUTPUT LOAD RANGE RIPPLE RIPPLE RANGE REGULATION VOLTAGE MAX. P-P MAX. +NOISE MIN. +3.3V 0.5A +4% ~ -4% 50mV 80mV 0.5A +5% ~ -5% 50mV...
  • Page 22 +10% ~ -9% 200mV 200mV 5V AUX 0.9A +5% ~ -5% 100mV 100mV Note : 1. +5V and 3.3V total combination output power should not over 205w. 2. The cross regulation is defined in the matrix below. H800 Server Chassis...
  • Page 23 2-17 Parts Description Conducted EMI : -FCC docket 20780. Part 15. Class B. -CISPR 22. Class B. -BZT vfg 243 Class B requirements -VCCI class 2 requirements. Product safety : this power supply is designed to meet the following specs. -UL 1950.3 .
  • Page 24: Drive Bays

    2.7. Drive Bays The H800 is consists of nine 5.25” drive bays and one 3.5” floppy drive bay. The nine 5.25” drive bays are designed horizontally on the front panel from top to bottom, while the 3.5” floppy drive is vertically designed on the upper right side of it. These drive bays can be installed by screw or slide rails.
  • Page 25: Installation

    Optional Parts Lists Installation 3.1. Opening Chassis Unlock the key lock on the front panel cover. Open the front cover to about 90 degrees and take it off. Unscrew the four thumb screws on the left and right side cover Pull the left and right side covers straight off to release them.
  • Page 26: Installing Motherboard Into Chassis

    AT, which can be integrated into a standalone or standard 19” rack mount, and thus greatly enlarges its working field. H800 provides an Intel standard I/O port bracket, please check the motherboard I/O port to see whether it can meet the size and port output or not. If not, you’ll have to get a correct one from motherboard accessory and change the port bracket before installing the motherboard.
  • Page 27: Fastening Slide Rails To Fdd And 5.25" Cd-Rom

    Optional Parts Lists 3.3. Fastening Slide Rails to FDD and 5.25” CD-ROM Secure each slide rails on the left and right side of FDD with four screws. Connect the FDD cable. Choose screw hole for slide rails and then secure each slide rails on the left and right side of 5.25”...
  • Page 28: Installing Fdd And 5.25" Cd-Rom Into Chassis

    Slide the 5.25” CD-ROM with slide rails into the drive bay. You may fasten the 5.25” CD-ROM with four screws if the slide rails are not available. The 1st location don’t support screw way, it just can support rail way only. H800 Server Chassis...
  • Page 29: Installing Hdd Cage Into Chassis

    Optional Parts Lists 3.5. Installing HDD Cage into Chassis Note: The hard disk is a sensitive mass storage device. Any accidentally impact on the hard disk might cause serious damage, so please handle it with care. Insert the 8cm fan into the HDD cage for a better heat-dissipation if necessary and fasten it with four screws.
  • Page 30: Final Assembly

    Connect cables to the correct position step by step according to the motherboard manual. Connect other devices (keyboard, mouse, monitor) and try to power on to check the system configuration. Slide the side panel and fasten it with thumbscrew before putting down the front panel and lock. H800 Server Chassis...
  • Page 31: Rack Mount Placement

    Optional Parts Lists 3.7. Rack Mount Placement Release all handle, wheels, and foot stands first. Release top cover. Screw off the top cover 6pcs screw then change the top cover to rack mount type and screw on. For another assembly please follow up rack mount kits install manual for detail.
  • Page 32: Explosive View, Parts And Icon

    3.8.1. Explosive view ITEM PARTS NAME Q’TY ITEM PARTS NAME Q’TY ASS’Y L-CASE ACER 002( C ) H800 SPRING EMI (LONG) PANEL ASS’Y BOX FOR H800 ACCESSORY SIDE COVER ASSY I/O BRACKET A3.2 HDD CAGE ASS’Y POWER SUPPLY RAIL ASS’Y...
  • Page 33: Parts

    Optional Parts Lists 3.8.2. parts FOOT STAND FOOT BASE P/N : 60.96512.011 P/N : 42.96504.001 MAIN BOARD I/O BRACKET FAN COVER A3.2 P/N : 60.96533.001 P/N : 42.96514.001 FDD RAIL RAIL P/N : 34.96508.001 P/N : 60.96505.001 EMI COVER THUMB SCREW P/N : 34.96504.001 P/N : 86.2R526.AR5 2ND FAN 500mm 3PIN...
  • Page 34: Accessory Box

    3-10 Optional Parts Lists 3.8.3. accessory box 3.8.4. icon H800 Server Chassis...
  • Page 35: Optional Parts Lists

    4.1. WH (wheels and Handle) kit (Optional) The H800 is convenient in transportation with two wheels at the lower front side and one handle at the rear panel side under power supply. Handle set : use 4 screw install handle set into chassis at rear panel...
  • Page 36: Rack Mount Assembly Kit

    Optional Parts Lists Wheels 4.2. Rack Mount Assembly kit The H800 can be easily served as a standalone or rack mount system. Detail please see the manual of Rack mount kit. H800 Server Chassis...
  • Page 37: Technical Support

    How to Get Technical Support Dear Customer, Thanks for choosing AOpen products. To provide the best and fastest service to our customer is our first priority. However, we receive numerous emails and phone-calls worldwide everyday, it is very hard for us to serve everyone on time. We recommend you follow the procedures below and seek help before contact us.
  • Page 38: How To Contact Us

    Fax: 49-2102-157799 America AOpen America Inc. Tel: 1-510-498-8928 Fax: 1-408-922-2935, 1-408-432-0496 Web Site: http://www.aopen.com.tw E-mail: Send us email by going through the contact form below. English http://www.aopen.com/tech/contact/techusa.htm Japanese http://www.aopen.co.jp/tech/contact/techjp.htm Chinese http://www.aopen.com.tw/tech/contact/techtw.htm German http://www.aopencom.de/tech/contact/techde.htm French http://france.aopen.com/tech/contact/techfr.htm Simplified Chinese http://www.aopen.com.cn/tech/contact/techcn.htm H800 Server Chassis...

Table of Contents