Installation Instructions

Installation Instructions

Safety instructions

Warning! This must be read!
The laws, ordinances, directives and standards in force in the country of use are
to be followed (safety regulations, proper recycling in accordance with the regu-
lations, etc.)
Installation may only be carried out by a qualified electrician.
The minimum distances to other appliances and units are to be observed.
Anti-shock protection must be provided by the installation, for example drawers
may only be installed with a protective floor directly underneath the appliance.
The cut surfaces of the worktop are to be protected against moisture using a
suitable sealant.
The sealant seals the appliance to the work top with no gap.
Avoid installing the appliance next to doors and under windows. Otherwise hot
cookware may be knocked off the rings when doors and windows are opened.
Risk of injury from electrical current.
• The appliance must be free of voltage when installing and uninstalling.
• Observe connection schematic.
• Observe electrical safety rules.
• Ensure anti-shock protection through correct installation by a qualified in-
staller.
• The appliance must be connected to the electrical supply by a qualified elec-
trician.
Risk of injury from electrical current.
Loose and inappropriate plug and socket connections can make the terminal
overheat.
• Have the clamping connections correctedly installed by a qualified electrician.
• Use strain relief clamp on cable.
• This appliance's mains cable is fixed directly to the board. If the mains cable is
damaged, it must only be replaced by a qualified ecletrician or our Customer
Care Department.
• This appliance's mains cable must be a special cable (type H05BB-F Tmax 90°;
or higher). The latter is available from the Customer Care Department.
A device must be provided in the electrical installation which allows the appli-
ance to be disconnected from the mains at all poles with a contact opening
width of at least 3 mm.
Suitable isolation devices include line protecting cut-outs, fuses (screw type fus-
es are to be removed from the holder), earth leakage trips and contactors.