Not Function Of The Gear Of The Fuser Due To Melting Away; Paper Empty; Paper Empty Without Indication - Samsung ML-1210 Service Manual

Ml-1200 series
Hide thumbs Also See for ML-1210:
Table of Contents

Advertisement

4-4-3 Not function of the gear of the fuser due to melting away

• Description
The motor breaks away from its place due to gear melting away.
Check and Cause
DCU Mode : Check if the Error States '60' '62' '68' occur.
Check the operation of Fuser Erasing Lamp On/Off with
the Error Code Check -10-.

4-4-4 Paper Empty

• Description
The paper lamp on the operator panel is on even when paper is loaded in the cassette.
Check and Cause
1. Bending or deformation of the actuator of the paper sen-
sor.
2. The function of the sensor board is defective Perform
DCU mode: Perform DCU diagnostic code 8.

4-4-5 Paper Empty without indication

• Description
The paper lamp on the operator panel does not come on when the paper cassette is empty.
Check and Cause
1. Bending or deformation of the actuator of the paper sen-
sor.
2. The function of the sensor board is defective Perform.
DCU mode : Perform DCU diagnostic code 8.
Samsung Electronics
Solution
1. Replace the Fuser.
(Service Parts : Figure 8-4, Chapter 5)
2. Replace the Main Control board.
(Service Parts : Figure 9, Chapter 5)
Solution
1. Replace the defective actuator.
(Service Parts : Figure 8-17, Chapter 5)
2. Replace the sensor board.
(Service Parts : Figure 8-10, Chapter 5)
Solution
1. Replace the defective actuator.
(Service Parts : Figure 8-17, chapter 5)
2. Replace the sensor board.
(Service Parts : Figure 8-10, chapter 5)
Troubleshooting
4-17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ml-1250Ml-1220m

Table of Contents