Appendix; General Troubleshooting - Chauvet LED PAR 56-24UVB User Manual

Table of Contents

Advertisement

5. A
PPENDIX

General Troubleshooting

5. Appendix

S
YMPTOM
• Excessive circuit load
Breaker/Fuse
• Short circuit along the power
keeps blowing
wires
• No power
Device does not
• Loose power cord
power up
• Wrong DMX addressing
• Damaged DMX cables
• Wrong polarity settings on the
Fixture is not
responding to DMX
controller
• Loose DMX cables
• Faulty DMX interface
• Faulty Main PCB
• Non DMX cables
• Bouncing signals
• Long cable / Low level signal
Loss of signal
• Too many fixtures
• Interference from AC wires
If you still have a problem after trying the above solutions, please contact CHAUVET®
Technical Support.
P
C
(
)
OSSIBLE
AUSE
S
• Check total load placed on the
• Check for a short in the electrical
• Check for power on Mains.
• Check power cord
• Check Control Panel and unit
• Check DMX cables
• Check polarity switch settings on
• Check cable connections
• Replace DMX input
• Replace Main PCB
• Use only DMX compatible cables
• Install terminator as suggested.
• Install amplifier right after fixture
• Install an optically coupled DMX
• Keep DMX cables separated from
11
P
A
(
)
OSSIBLE
CTION
S
electrical circuit.
wiring (internal and/or external).
addressing
the controller
with strong signal.
splitter after unit #32.
power cables or black lights.
9/13/2010 2:33 PM

Advertisement

Table of Contents
loading

Table of Contents