IP Configuration
MDS 05-4846A01, Rev. H
•
—The transceiver's buffer provides a way of handling data
Buffer
"over-runs," where more data is passing through the
than can be immediately handled by the unit. When the buffer is
on, any such data is stored up and processed in the appropriate
order. Available selections are
•
—This setting controls the device behavior of x710 legacy
Device
radios. It does not apply to packet or Ethernet radios, and may be
disregarded for these later models.
•
—Any combination of the three Virtual Radio
Talk on/Listen to
Channels may be entered in these fields. For more information on
how these settings are used, refer to the SD Serial/Telnet Manage-
ment Supplement, Part No. 05-6193A01 more information.
•
—Indicates whether the radio's terminal server is
Term Srvr Status
enabled or disabled.
NOTE: The radio can operate in RS-422 mode when RS-485 is
selected.
The
screens contain various settings for the IP data
IP Configuration
stream. Each item is listed below along with an explanation of the
parameter. Note that the top of the screen displays the current settings
that have been applied to the radio in a read-only fashion.
•
Current IP Address
programmed.
•
Current Subnet Mask
grammed.
•
Current Default Gateway
gateway programmed.
•
—The radio requires a local IP address to support
Static IP Address
remote management and serial device (terminal server) services.
An IPv4 IP address should be entered in this field, unless DHCP
is enabled, in which case it is not required.
SD Series Technical Manual
Data Handling ON
—Read-only indication of the current IP address
—Read-only indication of the subnet mask pro-
—Read-only indication of the current default
port
COM2
or
.
Data Handling OFF
69