To Program Relocking Timer
A.
Relay 1:Press「*100」(relay 1) or 「*200」(relay2) , Followed by the number of
seconds the relay should open→「05」=5 seconds(01 ~99 = seconds)→
(beep)→enrolled → Press 「#」 to exit from the programming mode.
B.
Enter「00」Sets the relay to latching mode. (Correct code entered opens the relay,
and the relay stays open until the correct code is entered again).
Changing the Master codes: (at programming mode)
Enter「*000」Followed by the new 5 digit master code→(beep)→enrolled→Enter
「#」 to exit from the programming mode.
Master Code reset to Factory default 「12345」
Insert the jumper P1 1-2 position5 beepsReset successful.
5. Wiring diagram:
For DC use only
Note:
It is suggested to use a linear power supply unit to prevent reading range reduction at
the card reader.
The suggested wire gauge is #22~26 AWG.
The door strike or relay must have a varistor or a diode across the door strike terminals
to suppress the back EMF of the strike-failure to do so will damage the relay contacts
and electronic components , or even burns the controller.