    Contents Page No. Short Description Safety Instructions Receiver Installation 4 - 8 Installation Continued 9 - 10 Setting The Time Set Heating ON/OFF Periods Set Max/Min Room Temperatures Manual Switch...
  • Page 3: Short Description

    The Radio Thermostat Mechanical Clock is a 7 day radio frequency (RF) wireless thermostat/ timer which communicates with a special receiver designed to replace the universal digital timer fitted to most of Ferroli’s combination boilers. The Radio Thermostat Mechanical Clock is battery powered and can be sited wherever conventional room thermostats would normally be sited.
  • Page 4: Receiver Installation

    Receiver Installation Rear View of Receiver Radio Thermostat Clock Receiver Live (Brown) - Terminal 1 Neutral (Blue) - Terminal 2 Switching wires - Terminals 3 & 4 Please note: If replacing universal digital timer, please ensure you now use terminals 3 & 4, instead of 3 & 5 as per universal digital timer.
  • Page 5 Optima 01 Range Universal Digital Clock Radio Thermostat Clock Receiver Step 1 Remove clock from control panel. Step 2 Swap wiring as shown. Make sure Live is connected to terminal 1 (wire colour is not conclusive of polarity) Step 3 Fit receiver into control panel. Note.
  • Page 6 Domina, Modena and Falcon Note. If the Radio thermostat clock is going to replace the existing room thermostat this must be linked out on the room thermostat terminal block. Universal Digital Clock Radio Thermostat Clock Receiver Step 1 Remove clock from control panel. Step 2 Swap wiring as shown.
  • Page 7 Optimax 25C Note. If the Radio thermostat clock is going to replace the existing room thermostat this must be linked out on the room thermostat terminal block. Universal Digital Clock Radio Thermostat Clock Receiver Step 1 Remove clock from control panel. Step 2 Swap wiring as shown.
  • Page 8 Optimax HE Range Step 1 Remove boiler outer case and lower control box. Step 2 Remove control box cover. Step 3 Connect brown and blue JST plug onto PCB terminal block X2. Step 4 Connect brown and blue onto receiver terminals 1 and 2. Make sure live is connected to terminal 1.
  • Page 9: Installation Continued

    Installation ATTENTION! Radio link installation 1. Press receiver button and hold down for 2 seconds. The LED flashes twice. Then release Button the button. The LED remains on between 1 and 10 seconds. When a correct link between the transmitter and receiver has been established the LED goes off.
  • Page 10 Installation Mounting the wall plate Battery installation Locate and fit the transmitter, taking into consideration where not to position the transmitter as shown. The following can reduce, deflect or block radio frequency signals between the transmitter and receiver. A. Steel reinforced walls. B.
  • Page 11: Setting The Time

    Setting the time Note: Panel (A) slides back to reveal reference instructions (B). Slide cover (D) off the transmitter. Turn the outer dial clockwise to set the clock hands to the correct time. Ensure the time corresponds with the correct time on the 24hr dial. 3.00pm = 15.00 not 3.00.
  • Page 12: Set Heating On/Off Periods

    Set Heating ON/OFF Periods Select the ON times by pushing the tappets to the outside. Select the OFF times by pushing the tappets to the inside. Above shows the clock set as follows: 3.00pm 10.00pm (15.00-22.00) 10.00pm 5.00am (22.00-5.00) 5.00am 8.00am (5.00-8.00) 8.00am...
  • Page 13: Set Max/Min Room Temperatures

    Set Max/Min Room Temperatures Maximum setting - Rotate the Maximum dial to give the required room temperature up to 30 when heating is on. Minimum setting - Rotate the Minimum dial to a lower temperature down to 5 C to ensure that when the heating is off a minimum room temperature is maintained.
  • Page 14 Notes...
  • Page 15 Notes...
  • Page 16 Should you require any assistance during the installation call our Technical Service Helpline on 08707 282 885 option 1 Ferroli Limited, Lichfield Road, Branston Industrial Estate, Burton-Upon-Trent, Staffordshire. DE14 3HD Service/Technical Tel: 08707 282 885 Fax: 08707 282 886...

Table of Contents