Generac Power Systems 6500XL 09779-2 Owner's Manual page 7

Generac portable generator user manual
Hide thumbs Also See for 6500XL 09779-2:
Table of Contents

Advertisement

Generac Portable P roducts 6500XL E xtended LifeGenerator
Stopping
the Engine
• Unplug all electrical loads from generator panel
receptacles.Never start or stop engine with electrical
devices plugged in and turned on.
• Put the idle control switch in the "Off"
position.
• Let engine run at no-load for 30 seconds to stabilize the
internal temperatures of engine and generator.
• Move run/stop switch to "Stop."
• Close the fuel shut-off valve.
Operating
Automatic
Idle Control
This switch is designed to greatly improve fuel economy.
When this switch is turned ON, the engine will only
run at its normal high governed engine speed when an
electrical load is connected.When an electrical load is
removed, the engine will run at a reduced speed. With the
switch off, the engine will run at the normal high engine
speed. Always have the switch off when starting and
stopping the engine.
Charging
a Battery
_
ARNING!
Storage batteries give off explosive
hydrogen gas while recharging.An explosive mixture
will remain around the battery for a long time after
it has been charged.The slightest spark can ignite
the hydrogen and cause an explosion, resulting in
blindness or other serious injury.
_
WARNING!
Do Not permit smoking, open
flame, sparks or any other source of heat around a
battery.Wear protective goggles,rubber apron and
rubber gloves when working around a battery.
Battery electrolyte fluid isan extremely caustic
sulfuric acid solution that can cause severe burns. If
spill occurs flush area with clear water immediately.
Your generator hasthe capability of recharging a discharged
12Volt automotive or utility style storage battery. Do Not
use the unit to charge any 6Volt batteries. Do Not use the
unit to crank an engine havinga discharged battery.
To recharge
12 Volt batteries, proceed as follows:
• Check fluid level in atl battery cells. If necessary,add
ONLY distilled water to cover separators in battery cells.
Do Not use tap water.
• If the battery isequipped with vent caps,make sure they
are installed and are tight.
• If necessary,clean battery terminals.
• Connect battery charge cable connector plug to panel
receptacle identified by the words "12 VOLTS D.C"
• Connect battery charge cable clamp with red handle to
the positive (+) battery terminal (Figure 6).
12 VOLT D.C.
RECEPTACLE
÷
POS
NEG
12VOLTBA'I-rERY
• Connect battery chargecable clamp with black handle
to the negative (-) battery terminal (Figure 6).
• Start engine. Let the engine run while battery recharges.
• When battery has charged, shut down engine
NOTE: Use an automotive hydrometer to test battery
state of charge and condition. Follow the hydrometer
manufacturer's instructionscarefully. Generally, a battery is
considered to be at 100%state of charge when specific
gravity of itsfluid (as measured by hydrometer) is 1.260or
higher.
/
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents