Burner characteristics
Normal
Burner
power
(MJ/h)
10,5
RAPID
10,5
SEMI-
RAPID
AUXILIARY
Before any modifications or
conversion to a kind of different
gas, you must DISCONNECT the
cooker from the electricity supply
and ensure that all control knobs
are in the OFF position, and the
appliance has cooled completely.
Replace the nozzles of the hob
burners
Hob burners
Remove the pan supports;
Remove the caps and the burner
crowns;
Using a No 7 socket spanner
unscrew the nozzles and replace
them with those required for the
type of gas in use (see burners
characteristics table above).
Reassemble the parts following the
same procedure in reverse.
These burners do not need any
primary air regulation.
14
Simmer
power
(MJ/h)
2,62
2,62
7,0
1,75
6,5
1,62
4,2
1,05
4,0
1,00
By-
pass
Gas Type
(mm)
Natural Gas
0,42
U-LPG
Natural Gas
0,35
U-LPG
Natural Gas
0,29
U-LPG
Nozzle
Pressure
diameter
(kPa)
(mm)
1,00
1,39
2,60
0,90
1,00
1,11
2,60
0,71
1,00
0,89
2,60
0,55