LP Gas Conversion Kits

Davies Supply Group Ltd.
For G6 & L1 Series Furnaces

Designed for Canadian installations. To convert a natural gas
furnace to LP/Propane gas for altitudes between 0 to 4,500
feet above sea level, the main gas orifice must be replaced.
For higher altitudes (between 2,000 & 4,500 feet above seal
level) the input must be de-rated by 10%. This can be done
by simply reducing the manifold pressure without changing
the gas orifices.

Use on standard & slow opening models only

Not for use with step regulator valves
For use with G6 & L1 series gas furnaces using a

For G7 Series Furnaces


Designed for Canadian installations to convert a natural gas
furnace to LP/Propane gas. Used for altitudes between 0 to
4,500 feet above sea level

For altitudes between 0 and 1,999 feet, only the orifice needs
to be changed. For altitudes between 2,000 and 4,500 feet,
both the orifice and the regulator pressure need to be
changed.
For use with G7 series gas furnaces using a

For G7MQ Modulating Furnaces

Calgary (800) 661-1346
(403) 244-2161

Furnace Accessories

Application
Honeywell Gas Valve
Application
Honeywell Gas Valve
Application
For use with G7MQ series gas furnaces
Lethbridge (877) 595-7707
(403) 381-7707
A45-1
Part
Brand
Number
Frigidaire
904091A
Part
Brand
Number
Frigidaire
904915
Part
Brand
Number
Frigidaire
904950
Saskatoon (877) 355-3377
(306) 933-2433

Advertisement

Table of Contents
loading

Table of Contents