Flue Gas Venting System - System 636™ PVC
Type BH Class IIA Vent: For use with gas fired appliances producing flue gases of 65
Complete system fully certified to ULC S636
White pipe with unique blue certification markings made to SCH 40 dimensions
Description
2" Flue Gas Venting System
2" Concentric Vent Termination Kit (no vent screen)
2" Wall Termination Kit (no vent screen)
2" x 10' Pipe (Straight End)
2" Coupling (HubxHub)
o
2" 45
Elbow (HubxHub)
o
2" 90
Street Elbow (SPxHub)
o
2" 90
Long Elbow (HubxHub)
o
2" 90
Extra Long Elbow (HubxHub)
2" Sanitary Tee (HubxHubxHub)
3" Flue Gas Venting System
3" Concentric Vent Termination Kit (no vent screen)
3" Wall Termination Kit (no vent screen)
3" x 10' Pipe (Straight End)
3" Coupling (HubxHub)
o
3" 45
Elbow (HubxHub)
o
3" 90
Street Elbow (SPxHub)
o
3" 90
Long Elbow (HubxHub)
o
3" 90
Extra Long Elbow (HubxHub)
3" Sanitary Tee (HubxHubxHub)
Adapters & Other Components
3" x 2" Increaser Coupling (HubxHub)
3" x 2" Reducer Tee (HubxHubxHub)
2" x 1 1/2" Reducer Bushing (SPxHub)
Used with #196278
1 1/2" x 1/2" Reducer Busing (SPxHose Barb)
2" Testing Plug & Bushing Kit (SPxPlug)
PVC Cement, Low VOC (1 pint/473ml)
PVC Cement, Low VOC (1 quart/946ml)
Transition Cement - To ABS Only (1 pint/473ml)
Primer should be used when installing System636 products at temperatures
below 0
PVC/CPVC Purple Primer, Low VOC (1 pint/473ml)
PVC/CPVC Clear Primer, Low VOC (1 pint/473ml)
PVC/CPVC Purple Primer, Low VOC (1qt/946ml)
Davies Supply Group Ltd.
Case Part Number
3
196005
1
081216
10
194000
70
196352
110
196242
60
196232
55
196122
40
196022
35
196082
3
196006
1
081219
10
194001
60
196353
25
196243
15
196233
23
196123
15
196023
17
196083
45
196364
10
196822
80
196282
80
196278
10
196143
Cement
12
196040
12
196041
12
196044
Primer
o
C
12
196042
12
196017
12
196043
Calgary (800) 661-1346
(403) 244-2161
o
C or less
Concentric Vent Kits
These "pipe-in-pipe" kits allow for both exhaust and intake pipes
to penetrate the roof or side wall through only one hole and are
certified with mechanically fastened rain caps
Screw/bolt assembly (included) for mechanically fastening the
rain cap can be easily removed for cleaning or maintenance
Wall Termination Kits
For a traditional vent style, IPEX's PVC Wall Termination Vent Kits
require only two small wall penetrations for intake and exhaust
Kits include a white finishing plate with a self sealing foam back
that can be screwed to the exterior wall
Testing Plug & Bushing Kit
Allows an inline access point for flue monitoring using fully
certified System 636 components. The kit consists of a 2" x 1/2"
reducer bushing (Spig x FPT) and a removable 1/2" MPT plug
May be installed in new installations or added to existing lines
when monitoring is required
Bushing must be inserted in a 2" fitting socket
May be used on vent lines in any diameter
Certified for use only on IPEX System 636 flue gas vent lines
Concentric Vent Kit
Wall
Termination
Testing Plug
Kit
NOTE!
1. Do Not interchange pipe, fittings or chemicals from
different BH vent manufactures. Doing so will void
System636™ product certification and warranty.
2. Contractors must check local codes for proper venting
Lethbridge (877) 595-7707
(403) 381-7707
A45-3
Furnaces
& Bushing
Kit
Saskatoon (877) 355-3377
(306) 933-2433