Alarm/Danger Levels - Kidde KN-OOB-B User Manual

Battery powered carbon monoxide alarm
Table of Contents

Advertisement

Alarm/Danger Levels

Caution: This CO alarm will only indicate the presence of
CO at the sensor. CO may be present in other areas.
Mild Exposure: Headaches, running nose, sore eyes,
often described as "flu-like" symptoms.
Medium Exposure: Dizziness, drowsiness, vomiting.
Extreme Exposure: Unconsciousness, brain damage,
death.
Familiarization with the effects of each level is important.
The symptoms described in the chart above are related to car-
bon monoxide poisoning and should be discussed with ALL
members of the household.
Exposure to high levels of carbon monoxide can be
fatal or cause permanent damage and disabilities.
Many victims of carbon monoxide poisoning indicate that
while they were aware that they were ill, they became so dis-
oriented and confused that they were unable to help them-
selves by exiting the building or calling for assistance. If you
experience any symptoms of carbon monoxide poisoning, con-
sult your doctor immediately! CO poisoning can be deter-
mined by a simple blood test called a carboxyhemoglobin test.
Severe cases may require treatment in a hyperbaric chamber.
Remember, young children and household pets may be the
first effected.
If you have additional questions please call the Kidde
Consumer Hotline at 1-800-880-6788.
11
Alarm/Danger Levels (cont.)
Concentration
of CO in Air
Approximate Inhalation Time
(ppm = parts
per million)
50 ppm
The maximum allowable concentration for
continuous exposure for healthy adults in
any 8-hour period, according to OSHA*.
200 ppm
Slight headache, fatigue, dizziness, nausea
after 2-3 hours.
400 ppm
Frontal headaches within 1-2 hours, life
threatening after 3 hours.
800 ppm
Dizziness, nausea and convulsions within 45
minutes. Unconsciousness within 2 hours.
Death within 2-3 hours.
1,600 ppm
Headache, dizziness and nausea within 20
minutes. Death within 1 hour.
3,200 ppm
Headache, dizziness and nausea within 5-10
minutes. Death within 25-30 minutes.
6,400 ppm
Headache, dizziness and nausea within 1-2
minutes. Death within 10-15 minutes.
12,800 ppm
Death within 1-3 minutes.
* Occupational Safety and Health Administration
WARNING: The chart above relates to healthy adults. Levels dif-
fer for those at high risk. This product is intended for use in
ordinary indoor residential areas. It is not designed to measure
compliance with commercial and industrial standards.
This device is designed to protect individuals from acute effects
of carbon monoxide exposure. It will not fully safeguard indi-
viduals with specific medical conditions. If in doubt, consult a
medical practitioner. Individuals with medical problems may
consider using warning devices, which provide audible and visu-
al signals for carbon monoxide concentrations under 30 ppm.
This CO alarm meets these alarm response times
At 70 PPM, the unit must alarm within 60-240 minutes
At 150 PPM, the unit must alarm within 10-50 minutes
At 400 PPM, the unit must alarm within 4-15 minutes