Replace Member Errors - Dell 6 series User Manual

Poweredge expandable raid controller
Table of Contents

Advertisement

Table 7-6. SMART Errors (continued)
Problem
A SMART error
occurs during a
Consistency Check
(CC)

Replace Member Errors

Table 7-7 describes issues related to the Replace Member feature.
NOTE:
For more information about the Replace Member features, see "Using
Replace Member and Revertible Hot Spares" on page 37.
Table 7-7. Replace Member Operation Errors
Problem
The source drive fails
during the Replace
Member operation.
Target drive fails
Other drives fail
126
Troubleshooting
Suggested Solution
Specify how the CC operation must perform when a SMART
error is encountered.
There are two settings, Yes and No. No is the default setting
and allows CC to continue when the first error is encountered.
The Yes setting halts CC when the first error is encountered.
Events are generated in the Event Log when errors are
encountered during CC.
Suggested Solution
If the source data is available from other drives in the virtual
disk, the rebuild begins automatically on the target drive, using
the data from the other drives.
If the target drive fails, the Replace Member operation aborts.
If the target drive fails and the Replace Member operation
aborts but the source data is still available, then the Replace
Member operation continues as Replace Member.

Hide quick links: