Smart Error - Dell 5 series User Manual

Expandable raid controller
Hide thumbs Also See for 5 series:
Table of Contents

Advertisement

Table 6-3. Physical Disk Failure and Rebuild Issues (continued)
Issue
A physical disk becomes
inaccessible during a
reconstruction process on a
redundant virtual disk that has
a hot spare.
A physical disk is taking longer
than expected to rebuild.

SMART Error

Table 6-4 describes issues related to the Self-Monitoring Analysis and Reporting Technology (SMART).
SMART monitors the internal performance of all motors, heads, and physical disk electronics and detects
predictable physical disk failures.
NOTE:
For information about where to find reports of SMART errors that could indicate hardware failure, see the
Dell OpenManage Storage Management documentation.
Table 6-4. SMART Error
Problem
A SMART error is detected on
a physical disk in a redundant
virtual disk.
A SMART error is detected
on a physical disk in a
non-redundant virtual disk.
74
Troubleshooting
Suggested Solution
The rebuild operation for the inaccessible physical disk starts automatically after
the reconstruction is completed.
A physical disk takes longer to rebuild when under high stress. For example, there is
one rebuild input/output (I/O) operation for every five host I/O operations.
Suggested Solution
Perform the following steps:
Force the physical disk offline.
1
Replace it with a new physical disk of equal or higher capacity.
2
Perform a rebuild.
3
See "Performing a Manual Rebuild of an Individual Physical Disk" on page 67 for
rebuild procedures.
Perform the following steps:
Back up your data.
1
Delete the virtual disk.
2
See "Deleting Virtual Disks" on page 67 for information on deleting a virtual disk.
Replace the affected physical disk with a new physical disk of equal or higher
3
capacity.
Recreate the virtual disk.
4
See "Setting Up Virtual Disks" on page 58 for information on creating virtual disks.
Restore the backup.
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge 5/ePoweredge 5/i

Table of Contents