Permeate Back Pressure Correction Factors - GE E2 Series Installation And Operation Manual

Water purification machines
Table of Contents

Advertisement

2.11

Permeate Back Pressure Correction Factors

It is often necessary to operate RO machines with permeate back pressure. Permeate back
pressure will decrease permeate production. See Table 2.5 (Permeate Back Pressure
Correction Factors) to calculate loss of permeate.
BACK
PRESSURE
10 psig (0.7 barg)
20 psig (1.4 barg)
30 psig (2.0 barg)
40 psig (2.7 barg)
50 psig (3.4 barg)
60 psig (4.1 barg)
WARNING:
WARNING:
Table 2.5
E2/EZ2-Series
Permeate Back
Pressure Correction
Factors
% LOSS OF
PERMEATE
FLOW
5%
10%
15%
20%
25%
30%
IF PERMEATE BACK PRESSURE EXCEEDS 60 PSI (4.1 BAR)
MACHINE DAMAGE MAY OCCUR.
INSTALLING A CHECK VALVE WILL PREVENT REVERSE
FLOW THROUGH THE MEMBRANE ELEMENT WHEN THE
MACHINE IS NOT IN OPERATION. REVERSE FLOW, WHEN
THE MACHINE IS NOT IN OPERATION, CAN SEVERELY
DAMAGE THE MEMBRANE ELEMENTS.
8
PRESSURE
CORRECTION
FACTOR (PCF)
0.95
0.90
0.80
0.70
0.60
0.50