Foxconn H67M Series User Manual page 102

User manual
Hide thumbs Also See for H67M Series:
Table of Contents

Advertisement

4. A "DeGRADeD VolUMe DeTeCTeD" screen pops out asking you to select a new
hard disk for rebuilding. Here, we select ST 74.5GB. Press <Enter> to select it.
Intel(R) Matrix Storage Manager option ROM v5.0.0.1011 ICH9R wRAID5
1. Create RAID Volume
2. Delete RAID Volume
"Degraded" volume and disk available for rebuilding detected. Selecting
3. Reset Disks to Non-RAID
RAID Volume :
ID
Name
0
TryRAID5
Physical Disks:
Port Drive Model
0
Hitachi HDS72161
1
ST380811AS
2
SAMSUNG HD161HJ S0V3J9APA30524
3
ST380815AS
5. It goes back to Main menu with a "Rebuild" status of RAID5 volume. Eventually,
a replacement hard disk has to join in and it always keeps three hard disks in the
RAID5 system.
6. Operating System will perform the rebuilding later.
Intel(R) Matrix Storage Manager option ROM v5.0.0.1011 ICH9R wRAID5
1. Create RAID Volume
2. Delete RAID Volume
RAID Volume :
ID
Name
0
TryRAID5
Physical Disks:
Port Drive Model
0
Hitachi HDS72161
1
ST380811AS
2
SAMSUNG HD161HJ S0V3J9APA30524
3
ST380815AS
Volume with "Rebulid" status will be rebuilt within the operating system.
Intel(R) Rapid Storage Technology - Option ROM - 10.0.0.1032
Copyright(C) 2003-10 Intel Corporation. All Rights Reserved.
Copyright(C) 2003-04 Intel Corporation All Rights Reserved.
[
MAIN MENU
[
DEGRADED VOLUME DETECTED
a disk initiates a rebuild. rebuild completes in the operating system.
Select the port of the destination disk for rebuilding (ESC to exit):
Port Drive Model
[
DISK/VOLUME INFORMATION
2
SAMSUNG HD161HJ
3
ST380815AS
Level
3
ST380815AS
RAID5(Parity)
Serial #
PVF904Z21G2JZM
[↑↓]-Previous/Next
[ENTER]-Select
5PS1TAGW
5RW1CA37
[↑↓]-Select
[ESC]-Exit
Intel(R) Rapid Storage Technology - Option ROM - 10.0.0.1032
Copyright(C) 2003-10 Intel Corporation. All Rights Reserved.
Copyright(C) 2003-04 Intel Corporation All Rights Reserved.
[
MAIN MENU
5. Exit
[
DISK/VOLUME INFORMATION
Level
RAID5(Parity)
Serial #
PVF904Z21G2JZM
5PS1TAGW
5RW1CA37
[↑↓]-Select
[ESC]-Exit
]
4. Recover Volume Options
]
5. Acceleration Options
6. Exit
Serial #
]
Size
S0V3J9APA30524
140.9GB
5RW1CA37
Stripe
Size
Status
74.5GB
5RW1CA37
74.5GB
64KB 149.1GB
Normal
Size
Type/Status(Vol ID)
149.0GB
Member Disk(0)
[ESC]-Exit
74.5GB
Member Disk(0)
149.0GB
Non-RAID Disk
74.5GB
Non-RAID Disk
[ENTER]-Select Menu
]
3. Reset Disks to Non-RAID
4. Recover Volume Options
]
Stripe
Size
Status
64KB 149.1GB
Rebuild
Size
Type/Status(Vol ID)
149.0GB
Member Disk(0)
74.5GB
Member Disk(0)
149.0GB
Non-RAID Disk
74.5GB
Member Disk(0)
[ENTER]-Select Menu
95
Bootable
Yes
Bootable
Yes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H67m-sH67m-v

Table of Contents