Checking the ground fault surveillance function:
When the NRS 90224 is installed and the power amplifier is switched on, the green READY indicator (7) has to light.
Utilizing an external switch to connect one pole of the 100V-loudspeaker network via a 47 k ohms resistor for
approximately 5 seconds to ground potential, the corresponding red GROUND FAULT indicator (6) has to light and the
READY fault message relay of the INPUT MODULE NRS 90225 drops while the green READY indicator (7) stays lit.
After releasing the button, the indication and the fault message are maintained. The TEST button (3) has to be used to
reset the ground fault surveillance function. For further details on checking the function with the REMOTE MODULE
NRS 90222 being included in your installation, please refer to the PROMATRIX handbook.
9.
19"-case and 19"-rack-shelf system installation
Note
Operation of the power amplifiers DPA 4120 and DPA 4140 with enclosure cover plates detached is
strictly prohibited.
When mounting the power amplifiers within rack-cases or rack-shelf systems make sure to provide sufficient airflow.
The space between the rear panel of the amplifier and the inner wall of the rack-case has to be at least 60 mm x 330
mm. A free space of at least 100 mm above the rack-shelf system is needed to provide sufficient air circulation. Since
it is possible that during operation the temperature inside the rack system increases by 10° C, the maximum
allowable ambient temperatures of the rest of the incorporated modules and appliances within a specific rack-shelf or
rack-case have to be taken into careful consideration.
Note
To ensure trouble-free operation of the appliance, the maximum permissible ambient temperature of
+40°C is not to be exceeded.
10.
Ground lift switch CIRCUIT
The ground lift switch CIRCUIT
from the enclosure (ground potential). This is mainly meant to eliminate noise-problems which are introduced through
ground-loops, without jeopardizing the security. In case several appliances within a single rack-case or rack-shelf are
furnished with ground lift switches, it is recommended to set all devices but one to "ungrounded". Set one appliance to
"grounded". When set to "ungrounded", the impedance between signal ground and enclosure is : 100 k ohms // 100
nF. It is needed to maintain EMV protection.
11.

Fuses

11.1 Fuses in the DPA 4120

location
fuse socket (11)
fuse socket (11)
printed board assembly
86243
printed board assembly
85270
printed board assembly
85270
11.2 Fuses in the DPA 4140
location
fuse socket (11)
fuse socket (11)
printed board assembly
86243
printed board assembly
85268
printed board assembly
85268

TO CHASSIS SWITCH

TO CHASSIS SWITCH (19) provides the possibility to separate the signal ground
Pos.
purpose
F601 mains fuse 230V~ AC
F601 mains fuse 115V~ AC
F602 mains fuse 100V - 250V
F502 battery fuse 24V DC
F503 battery fuse 24V DC
Pos.
purpose
F601 mains fuse 230V~ AC
F601 mains fuse 115V~ AC
F602 mains fuse 100V - 250V
F502 battery fuse 24V DC
F503 battery fuse 24V DC
value
dimensions
T2A
5x20 mm
T4A
5x20 mm
T1A
Ø 8.5xRM 5.08mm
15A
flat fuse
15A
flat fuse
value
dimensions
T4A
5x20 mm
T8A
5x20 mm
T1A
Ø 8.5xRM 5.08mm
25A
flat fuse
25A
flat fuse
39
standard
IEC 127-2-3
IEC 127-2-3
IEC 127-3/4
DIN 72581-3
DIN 72581-3
standard
IEC 127-2-3
IEC 127-2-3
IEC 127-3/4
DIN 72581-3
DIN 72581-3