Piping And Drain Hose Installation - Toshiba Carrier RAS-09 Installation Manual

Split type
Hide thumbs Also See for Carrier RAS-09:
Table of Contents

Advertisement

CAUTION
When installing the mounting plate with a mounting screw, do not use the
anchor bolt holes. Otherwise, the unit may fall down and result in personal
injury and property damage.
Installation plate
(Keep horizontal direction.)
3/16 in. (5 mm) dia. hole
Clip anchor
(fi eld supplied parts)
CAUTION
Failure to fi rmly install the unit may result in personal injury and property
damage if the unit falls.
• In case the unit is to be installed in a block, brick, concrete or similar type
walls, make 3/16 in. (5 mm) dia. holes in the wall.
• Insert clip anchors for appropriate mounting screws 7.
NOTE
• Secure four corners and lower parts of the mounting plate with 4 to 6
mounting screws to install it.
Wiring Connection
How to connect the connecting cable
1. Open the air inlet grille upward.
2. Remove the screws securing the front panel.
3. Slightly open the lower part of the front panel, then pull the upper part of
the front panel toward you to remove it from the rear plate.
4. Insert the conduit pipe (according to local codes) into the pipe hole on
the wall.
5. Remove the conduit mount by loosening the fi xing screw (Fig. 1)
6. Fix conduit pipe to conduit mount with the lock nut.
7. Pull out the connecting wire through the conduit pipe and process the
wire. (Fig. 3)
8. Take out the wire to the front and fi x it to the terminal block.
Be careful not to mis-wire. (Fig. 2)
9. Firmly tighten the terminal screws to prevent them from loosening.
Tightening torque: 0.9 lbf.ft (1.2 N·m). After tightening, pull the wires
lightly to confi rm that they do not move.
10. Secure the connecting wire with the cord clamp.
11. Fix the conduit mount back to the body by fi xing a screw.
12. Fix the front panel, terminal cover and air inlet grille to the indoor unit.
Air inlet grille
2
CAUTION
• Be sure to refer to the system wiring
diagram located inside the front panel.
• Check local electrical codes and also
any specifi c wiring instructions or
limitations.
1110251291-1 EN.indd 9
1110251291-1 EN.indd 9
Anchor bolt
Projection
9/16 in. (15 mm)
or less
7
Mounting screw
Ø5/32 in. × 1 in.
(Ø4 mm × 25 mm)
Front panel
1
3
Fig. 3
Ground
4-5/16 in. (110 mm)
line
13/16 in. (20 mm)
S
L
2
L
1
3/8 in. (10 mm)
3-5/32 in. (80 mm)
Fig. 1 Construction
Interconnecting
cable
Fixing screw
Fig. 2 Wiring
Cord clamp
Terminal cover
Screw
L
1
Screw
Screw
Front panel
NOTE
• Use stranded wire only.
• Wire type : minimum AWG14
How to install the air inlet grille on the indoor
unit
• When attaching the air inlet grille,
perform the same process as for
removal but in reverse order.

Piping and Drain Hose Installation

Piping and drain hose forming
INSULATE BOTH LINES.
Rear right
Rear left
Bottom left
Left
Bottom right
Right
Right
Rear right
Bottom
Rear
right
left
Bottom left
9
Lock nut
Conduit pipe
Conduit mount
Terminal block
L
L
1
S
2
L
2
S
Ground line
Connecting cable
Left
11/13/13 2:52 PM
11/13/13 2:52 PM
EN
SI

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents