If Vertically Venting:
Follow the vent length specifications in table on
page 9 and use a listed vent cap.
MANUFACTURED HOME
( MOBILE HOME ) and
RECREATIONAL PARK TRAILERS
WARNING : Read and Review this entire Manual
with special emphasis on the Combustion and
Ventilation for your safety.
This appliance must be installed in accordance with
the Manufactured Home Construction and Safety
Standard (Title 24, CFR ; Part 3280 ) and ANSI
A119.5 for Recreational Park Trailers, the following
instructions supplied with the vent termination, local
codes and utility company requirements governing
the installation of water heaters in manufactured
home ( mobile home ) and Recreational Park
Trailers and/or in the absence of local codes, the
latest edition of the National Fuel Gas Code, ANSI
Z 223.1/NFPA 54 and ANSI A119.5/NFPA 501D.
Location for a Manufactured Home (Mobile
Home) and Recreational Park Trailers
This water heater must be installed within an
enclosure
to
separate
combustion and venting system from the interior
atmosphere of the manufactured home or trailer. All
air for combustion must be obtained from the
outside
atmosphere.
combusted gases ( flue gases ) must be discharged
directly to the outside through the gas vent. There
must not be any door or other opening into the
water heater enclosure from the inside of the
manufactured home. Please refer to installation
diagrams and freeze protection information
Placement of Water Heater: Locate the water
heater as desired, make certain the minimum
clearances are maintained. For indoor installation
follow page 7-9, and outdoor installation follow page
6-7, please see section for manufactured home and
recreational park trailer outdoor installation.
Indoor installation for a Manufactured Home
(Mobile Home) and Recreational Park Trailers
Same as typical house installation except, all air for
combustion must be obtained from the outside
atmosphere for manufactured home.
Please see page 8 for indoor installation.
the
water
heater's
And
the
products

GAS SUPPLY AND PIPING

This unit requires a gas control shut-off valve to be
supplied by the installer. It must be placed on the
unit before it is connected to the gas line.
Check that the gas inlet pressure and the type of
gas matches the rating plate located on your water
heater. Insufficient gas pressure will cause your
AQ240FX Water Heater to be inefficient and not
work properly. Size the gas piping correctly.
For up to 25ft. ¾" Black Iron pipe is the
minimum pipe size required for Natural Gas.
For up to 25ft. ½" Black Iron is the minimum
pipe size required for LP.
For up to 10ft. 5/8" Copper is the minimum pipe
size required for LP.
Flex lines are not recommended, oversize if one
needs to be used.
See Gas Sizing tables on page 11.
Minimum and maximum inlet gas pressures are as
follows:
Natural Gas
Propane Gas
of
Maximum gas pressures must not exceed this
value.
After the connections are complete check for gas
leaks by applying soapy water to all gas fittings and
connections. Soap bubbles are a sign of gas leaks.
This appliance must be isolated from the gas supply
piping
system
disconnecting the main gas during any pressure
testing of the gas supply piping system at test
pressures equal to or more than ½ Psi. The
appliance and its gas connections must be leak
tested before placing the unit in operation.
Always use approved connectors to connect the
unit to the gas line. Always purge the gas line of
any debris before connection to the heater.
WARNING: Conversion of this unit from natural gas
to propane or propane to natural gas cannot be
done. Contact your local retailer or distributor to get
the correct unit for your gas type.
10
Min. 5" WC
Max. 10.5" WC
Min. 11" WC
Max. 14" WC
by
unplugging
the
unit
and