Installing Your Appliance - Westinghouse WFE912SA User Manual

900mm cooking appliances
Hide thumbs Also See for WFE912SA:
Table of Contents

Advertisement

INSTALLATION OF THE APPLIANCE
INSTALLING SPLASHBACK (MODELS WITH HOB ONLY)
Fit splashback to rear of hob with three screws provided.
CABINET REQUIREMENTS
Models WFE912, WFE914, WFE916, & WFE946 are
designed to fit into a 900mm wide gap between standard
kitchen cabinets. The appliance integrates with the kitchen
cabinets by matching the height, depth and kick panel.
The cooker may also be installed at the end of a line of
benches or with a free space either side. In addition, a
slot-in type installation is catered for allowing a continuous
cabinetry kick panel to be used. Model WVE916
is designed to be built into cabinetry either below a
benchtop or into a vertical cabinet.
• For model WFE946, the minimum clearance to a side
wall which extends above the ceramic cooktop is
100mm.
WARNING
• T he cooker must be installed and serviced only by an
authorised person
• A Certificate of Compliance MUST be supplied to be
kept by the customer
• T he packing materials must be removed before you
install the cooker
• T he surrounding kitchen cabinets must be able
to withstand 85°C. Electrolux WILL NOT accept
responsibility for damage caused by installation into
kitchen cabinets which cannot withstand 85°C.
• T he pipes used for installation MUST have sufficient loops
so the cooker can be moved for service (gas models).
• T he vents, openings and air spaces MUST NOT be blocked.
• T he anti-tilt brackets and chain or front stops MUST be
installed to avoid accidental tipping (floor mounted
and slot-in models)
• Y ou MUST NOT lift or pull the cooker by the door handle
• The cooker MUST be checked every five years
PROBLEMS
36
GAS MODEL CLEARANCE REQUIREMENTS
MODELS WFE912, WFE914 &WFE916
• E nsure the appliance is installed in accordance with
clauses 6.2.5 and 6.10.1.1 of AS/NZS 5601.1 or
clauses 6.9.1 and 6.9.5 of AS/NZS 5601.2 with
regard to clearances to combustible surfaces and
materials, and clearances to rangehoods and exhaust
fans, to ensure clearances of 200mm from burners
to vertical combustible surfaces observe the minimum
dimension of 100mm from each side of the cooker to
combustible surfaces.
• C learances to combustible surfaces may be reduced
if combustible surfaces are protected in accordance
with clause 6.10.1.2 of AS/NZS 5601.1, or clause
6.9.2 of AS/NZS 5601.2.
• W hen setting the cooker height, ensure the top of
the cooker is at least 10mm higher than the level
of the benchtop.
600mm
Gas hob 910mm
(adjustable 910 - 930mm)
Ceramic hob 906mm
(adjustable 906 - 926mm)
895mm
60mm
15mm (height of
trivet above hob)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wfe914saWfe916saWfe946saWve916sa

Table of Contents