This motor has a manual thermal
overload protector. If the motor
overheats for any reason, the
overload protector will shut off the
motor. The motor must be allowed
to cool down before restarting. To
restart:
1.
Place the On/Auto/Off lever in
the "Off" postion.
2.
Allow the motor to cool.
3.
Depress the red reset button on
the motor.
4.
Place the On/Auto/Off lever in
the "On/Auto" postion to restart
the motor.
4.
Using an adjustable wrench
loosen pressure relief tube nut at
air tank and pressure switch.
5.
Lift retaining clip from handle and
remove handle.
6.
Using an adjustable wrench,
rotate the pressure switch
assembly as shown.
7.
Remove the outlet pressure
gauge, tank pressure gauge, and
quick connect (if equipped) from
the regulator.
8.
Remove the regulator.