INSTALLING
Continued
101741
9. Check all gas connections for leaks. See Checking Gas Connections, page 18.
Figure 10 - Inserting Fireplace Into Cabinet Mantel

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves installing fireplace into a framed-in
enclosure. This makes the front of fireplace flush with wall. If installing a mantel above
the fireplace, but you must follow the clearances shown in Figure 15, page 15. Follow
the instructions below to install the fireplace in this manner.
IMPORTANT:
For built-in installation, nailing flange accessory G3004 is required. Do
not attach brass trim to fireplace for built-in installation.
Height
Actual Framing Actual
3
32
/
" 33"
8
1. Frame in rough opening. Use dimensions shown in Figure 11 for the rough
opening.
Figure 11 - Rough Opening for Installing in Wall
If installing in a corner, use dimensions shown in Figure 12 for the rough opening.
The height is 33" which is the same as the wall opening, above.
Figure 12 - Rough Opening for Installing in Corner
Front Width
Framing Actual
5
1
34
/
" 35
/
"
16
2
17 3/4"
33"
35 1/2"
39 3/8"
35 1/2"
55 5/8"
Depth
Framing
3
11
16
/
" 17
/
"
16
4
27 7/8"
Continued