GE RB533 Owner's Manual page 30

Electric ranges
Hide thumbs Also See for RB533:
Table of Contents

Advertisement

Installation of the range.
Read these instructions completely and carefully.
3
Power Cord Strain Relief Installation
Remove the lower rear range wiring cover to expose the connector block
a
and bracket.
Remove the knockout ring (1
b
connector. To remove the knockout, use a pair of pliers to bend the
knockout ring away from the bracket and twist until ring is removed.
Knockout ring in bracket.
Assemble the strain relief in the hole. Insert the power cord through the
c
strain relief and tighten. Allow enough slack to easily attach the cord
terminals to the connector block. If tabs are present at the end of the winged
strain relief, they can be removed for better fit.
NOTE: Do not install the power cord without a strain relief. The strain relief bracket should
be installed before reinstalling the rear range wiring cover.
Wiring cover
(shown removed)
30
3
Connector box
Strain relief
²) located on bracket directly below the
8
Knockout ring removed.
Ground
strap
Bracket
Strain relief bracket
Power cord
(Provided with range cord. Not part of range.)