3-4. Connecting Spool Gun To Millermatic 211 Auto-Sett

.
Be sure that gun end is tight against drive assembly.
Incorrect
Gun Not Seated
OM-234 016 Page 14
6
1
3
7
4
Exposed O-rings
will cause shielding
gas leakage.
5
4
2
4
Correct
Gun Fully Seated
1
Drive Assembly
2
Spool Gun
3
Gun Securing Knob
4
Gun End
Loosen thumbscrew. Insert end
through opening until it bottoms
against drive assembly. Tighten
gun securing knob.
Spool gun must be inserted
completely to prevent leakage of
shielding gas.
5
Gun Trigger Plug
Insert plug into receptacle, and
tighten threaded collar.
6
Polarity Changeover Terminal
Block
To make proper polarity connection,
see welding power source Owner's
Manual .
7
MIG Gun/Spool Gun Switch
Place switch in Spool Gun position.
Close door.