Image Renew 631 User Manual
Image Renew 631 User Manual

Image Renew 631 User Manual

Hydrotherapy spa

Advertisement

Model No. PFSW62800
PFSB62800
PFSG62800
Serial No.
The serial number is on a plastic sign
inside the spa behind the access
panel. Write the serial number in the
space above.
Access
Panel
QUESTIONS?
As a manufacturer, we are com-
mitted to providing complete
customer satisfaction. If you
have questions, or if there are
missing parts, we will guarantee
complete satisfaction through
direct assistance from our factory.
TO AVOID UNNECESSARY
DELAYS, PLEASE CALL DIRECT
TO OUR TOLL-FREE CUSTOMER
HOT LINE. The trained techni-
cians on our customer hot line
will provide immediate assis-
tance, free of charge to you.
CUSTOMER HOT LINE:
1-877-897-7493
Mon.–Fri., 6 a.m.–6 p.m. MST
CAUTION
Read all precautions and instruc-
tions in this manual before using
this equipment. Save this manual
for future reference.
USER'S MANUAL
Visit our website at
www.proform.com
new products, prizes,
fitness tips, and much more!

Advertisement

Table of Contents
loading

Summary of Contents for Image Renew 631

  • Page 1 Model No. PFSW62800 PFSB62800 PFSG62800 Serial No. USER’S MANUAL The serial number is on a plastic sign inside the spa behind the access panel. Write the serial number in the space above. Access Panel QUESTIONS? As a manufacturer, we are com- mitted to providing complete customer satisfaction.
  • Page 2: Table Of Contents

    Table of Contents Posting the Warning Sign ..............2 Important Safety Instructions .
  • Page 3: Important Safety Instructions

    Important Safety Instructions WARNING: To reduce the risk of drowning, electric shock, or serious injury, read the fol- lowing important precautions before using the hydrotherapy spa. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure 10.
  • Page 4 20. DANGER—Risk of electric shock. Keep all physician before using the hydrotherapy spa. electrical appliances such as radios, tele- Pregnant women should not use the spa if phones, televisions, and lights at least five the water temperature is above 100°F; the feet away from the water.
  • Page 5 35. WARNING: The spa jets produce a stream of water with relatively high pressure. Prolonged exposure of a localized area of the body may cause bruises to the skin. 36. The included warning sign must be posted where all users of the hydrotherapy spa can see and read it.
  • Page 6: Before You Begin

    Before You Begin Congratulations for selecting the new PROFORM ® For your benefit, read this manual carefully before hydrotherapy spa. The innovative PROFORM ® using the PROFORM ® 6.0. If you have questions after allows you to enjoy all the benefits of hydrotherapy in reading the manual, please call our Customer Service the comfort and privacy of your home.
  • Page 7: Choosing A Location For The Hydrotherapy Spa

    Choosing a Location for the Hydrotherapy Spa There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where to set up the spa.
  • Page 8: Assembly

    Assembly Before beginning assembly, carefully read the ASSEMBLY REQUIRES THE FOLLOWING following information and instructions: TOOLS (not included): • Place all parts in a cleared area and remove the • One phillips screwdriver packing materials from the spa shell. Do not dis- pose of the packing materials until assembly is •...
  • Page 9 3. The hydrotherapy spa operates on a 240 volt power source and must be wired directly to a 240 volt Ground Fault Circuit Interrupter (GFCI) installed in your home. This procedure must be performed by a qualified, licensed electrician. A wiring diagram is found on the inside of the electronics package for reference. Under no circumstances should the spa be wired by someone other than a qualified electrician.
  • Page 10: Using The Hydrotherapy Spa

    Using the Hydrotherapy Spa The hydrotherapy spa is designed to seat six adults. If the level is too high, add half of one of the “QUICK The spa holds 375 gallons of water and offers a heat- pHix It DOWN” packets to the water. Let the water cir- ing system (80°F to 104°F), a filtration system, and culate through the spa for five minutes.
  • Page 11: Spa Shell Diagram

    Spa Shell Diagram Seat 1 Seat 2 Seat 3 Seat 4 Seat 6 Seat 5 A. The filter can be removed for cleaning or replace- ria while breaking down chemicals and solids for ment (see CHECKING AND CLEANING THE FIL- easy removal by the filtration system.
  • Page 12: Using The Controls

    Using the Controls Air Controls Air Controls Display Pump/Light Temperature Button Button Refer to the diagram above. The function of each 104°F. The water heats at about 6°F per hour with the control is explained below: cover on. Use a medical or other accurate thermome- ter to check the temperature of the water.
  • Page 13: Maintenance

    Maintenance The hydrotherapy spa is designed to provide years of entirely. Use a non-silicone-based vinyl conditioner on enjoyment. Please follow the guidelines below to the cover after you clean it. This will help protect the properly maintain your spa. cover from sun damage. MAINTENANCE SCHEDULE SANITIZING THE HYDROTHERAPY SPA Daily...
  • Page 14 WATER CHEMISTRY ATTACHING AND REMOVING THE ACCESS PANEL The hydrotherapy spa comes with a starter chemical Turn off the spa power. To remove the access panel, pack for maintaining the water in the spa. (See TEST- insert your fingers into the indicated holes. Pull the ING AND TREATING THE WATER on page 10.) top of the access panel away from the spa.
  • Page 15 To drain the hydrotherapy spa, follow the steps below: WINTER USE AND CARE 1. Using the console, adjust the temperature to the The hydrotherapy spa is designed for year-round use. lowest setting. If you decide to store the spa for the winter, store it in 2.
  • Page 16: Trouble-Shooting

    Trouble-shooting Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time. 1.
  • Page 17 10. SYMPTOM: THE SPA JET UNIT CONTINUES Overheating may occur if the filter cycle is set too TO RUN AFTER IT HAS BEEN SHUT OFF long. At 110° F the spa should reset itself. If the high-limit sensor detects 118° F at the heater, the a.
  • Page 18: Part List

    Part List Model No. PFSW62800, PFSB62800, PFSG62800) R0201A Key No. Qty. Description Key No. Qty. Description Thermometer Fitting Power Massage Jet 4-wire Power Cord 1/4” Lock Washer Round Weir Light Fixture Basket, Top Mount Volcano Jet Access Panel Buckle Spacer Ring #4 x 3/4”...
  • Page 19: Exploded Drawing

    Exploded Drawing Model No. PFSW62800, PFSB62800, PFSG62800) R0201A 29 18...
  • Page 20: Ordering Replacement Parts

    Ordering Replacement Parts To order replacement parts, simply call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays). To help us assist you, please be pre- pared to give the following information when calling: 1.

Table of Contents