Installation; Tools And Materials Required; Electrical Locations - GE Monogram ZEK737WW Installation Instructions Manual

27" built-in ovens
Hide thumbs Also See for GE Monogram ZEK737WW:
Table of Contents

Advertisement

Tools and
• Outlet box
materials
• Electrical cable—3-conductor or 4-conductor wire—as required
required
• Flexible power cable connector
• Electrician's pliers
Note:
cord with these appliances.
Electrical
locations
The back of the ovens have chamfered corners which
provide a "chase" for the conduit when installing a
junction box above or below the oven(s).
The conduit is located on the back of the oven,
approximately 10" from the right side.
For double oven:
• Locate and install the junction box within reach of
For single oven:
• Locate and install the junction box within reach of
16
by local codes
Do not use an extension
the power cord.
– Approximately 10" from the left side of opening
– 56" minimum above the cutout floor
– or, through the left side of cabinet wall into
adjacent cabinet.
the power cord.
– Approximately 10" from left side of opening.
– At least 5" below the cutout floor
– Or 34" minimum above the cutout floor
– or, through the left side of cabinet wall into
adjacent cabinet.

Installation

Built-In Ovens
Monogram built-in single and double ovens require
a separate, properly grounded 3-wire 120/208 or 120/
240 volt, 60 Hz power supply, protected by a time
delay fuse or circuit breaker. Ovens are supplied with a
flexible power cable, which must be attached to a
junction box. The cable length is 48" for both single
and double conventional ovens. The cable length for
convection type ovens is 54".
Double ovens are rated 6.8 KW at 240 volt, and 5.1 KW
at 208 volt.
Single ovens are rated 3.4 KW at 240 volt, and 2.6 KW
at 208 volt.
Double Oven:
Locate Junction Box
in one of the locations
Single Oven:
Locate Junction Box
in one of the locations

Hide quick links:

Advertisement

Table of Contents
loading