FIREPLACE FRAMING SPECIFICATIONS
EDVST
11-3/8
(See-Through)
10-1/2
(267)
7
(178)
12-1/8
(308)
7
(178)
5-1/8
(130)
12-1/8
(308)
5-1/8
26-3/4
(679)
(130)
Gas Line
Center of gas line
is 3 in. (76 mm)
up from floor.
Dimension A
Secure Vent - 47-1/8 (1197)
***48-1/2
Secure Flex - 47-3/4 (1213)
(1232)
***Provide Additional Space For Side Vent
Seal Cap If Installing Against A Solid Wall
**This dimension based on 5/8" drywall.
For 1/2" drywall use 23".
*This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm)
clearance between framing and unit framing spacers. (The 41-1/2 in. dimension permits
easier fireplace installation, if unit is installed after framing is erected.)
Figure 13
EDVCL (Corner-Left)
10-3/8
(
264
inches (millimeters)
10-1/2
Minimum Framing
(
)
267
Stud Size is 2x4
5-1/4 (133)
VENT FRAMING -
TOP VENT WITH
ONE 90º ELBOW
7
(178)
5-1/8
12-1/8
(130)
(308)
A
*41-1/2
(1054)
9-3/4
(248)
24
(610)
*This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm) clearance
between framing and unit framing spacers. (The 4-1/2 in. dimension permits easier fireplace
installation, if unit is installed after framing is erected.)
Figure 15
inches (millimeters)
Minimum Framing
Stud Size is 2x4
VENT FRAMING -
TOP VENT WITH
ONE 90º ELBOW
VENT FRAMING -
REAR VENT WITH
NO ELBOWS
A
6-1/4
(159)
**22-3/4
(578)
Dimension A
Secure Vent - 47-1/8 (1197)
)
Secure Flex - 47-3/4 (1213)
12-1/2
(318)
VENT FRAMING -
REAR VENT WITH
NO ELBOWS
10-1/2
(
267
)
5-1/4
(133)
7
(178)
5-1/8
(130)
26-3/4
(679)
Gas Line
Center of gas line
is 3 in. (76 mm)
up from floor.
6-1/4
(159)
**43-5/8
(1108)
Optional Gas Line Location
Center of gas line is 3 in. (76 mm)
up from floor.
**Provide Additional Space For Side Vent
Seal Cap If Installing Against A Solid Wall
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
EDVPF
(Peninsula)
7
(178)
12-1/8
(308)
7
(178)
5-1/8
(130)
12-1/8
(308)
5-1/8
(130)
*41-1/2
Gas Line
(1054)
Center of gas line
is 3 in. (76 mm)
up from floor.
Dimension A
Secure Vent - 47-1/8 (1197)
Secure Flex - 47-3/4 (1213)
***Provide Additional Space For Side Vent
Seal Cap If Installing Against A Solid Wall
**This dimension based on 5/8" drywall.
For 1/2" drywall use 23".
*This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm)
clearance between framing and unit framing spacers. (The 41-1/2 in. dimension permits
easier fireplace installation, if unit is installed after framing is erected.)
Figure 14
EDVCR (Corner-Right)
inches (millimeters)
Minimum Framing
Stud Size is 2x4
VENT FRAMING -
REAR VENT WITH
NO ELBOWS
7
(178)
12-1/8
12-1/8
(308)
(308)
5-1/8
(130)
**43-5/8
(1108)
Gas Line
Center of gas line is
3 in. (76 mm) up from floor.
**Provide Additional Space For Side Vent
Seal Cap If Installing Against A Solid Wall
*This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm) clearance
between framing and unit framing spacers. (The 41-1/2 in. dimension permits easier fireplace
installation, if unit is installed after framing is erected.)
Figure 16
11-3/8
inches (millimeters)
(289)
Minimum Framing
10-1/2
Stud Size is 2x4
(267)
VENT FRAMING -
TOP VENT WITH
ONE 90º ELBOW
VENT FRAMING -
REAR VENT WITH
NO ELBOWS
A
26-3/4
(679)
6-1/4
(159)
**22-3/4
(578)
***43-5/8
(1108)
Dimension A
10-3/8
Secure Vent - 47-1/8 (1197)
(
)
264
Secure Flex - 47-3/4 (1213)
10-1/2
(
)
267
12-1/2
5-1/4
(318)
(133)
10-1/2
(
)
267
5-1/4
7
(133)
(178)
5-1/8
(130)
26-3/4
(679)
A
*41-1/2
(1054)
*41-1/2
(1054)
VENT FRAMING -
TOP VENT WITH
ONE 90º ELBOW
12-1/8
(308)
9-7/8
(251)
24
(610)
11