Level
Standby w. remote Power Off via NomadLink
Power On, Idling
Pink noise
(1/8)
Pink noise
(1/4)
*1) The ampli er's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured and
speci ed here is what is known as the "Active Power" in the ampli er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw gures measured at 230 V. 115 V gures are 230 V gures multiplied by two.
35
C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4
Load
Rated power
120 VAC
70 V / Ch.
125
x4
1,7
16 Ω / Ch.
125
x4
1,5
32 Ω / Bridged
250
x2
100 V / Ch.
250
x2
1,4
8 Ω / Ch.
125
x4
1,3
16 Ω / Bridged
250
x2
4 Ω / Ch.
125
x4
1,3
8 Ω / Bridged
250
x2
2 Ω / Ch.
63
x4
0,9
4 Ω / Bridged
126
x2
70 V / Ch.
125
x4
3,0
16 Ω / Ch.
125
x4
2,4
32 Ω / Bridged
250
x2
100 V / Ch.
250
x2
2,3
8 Ω / Ch.
125
x4
2,0
16 Ω / Bridged
250
x2
4 Ω / Ch.
125
x4
2,1
8 Ω / Bridged
250
x2
2 Ω / Ch.
63
x4
1,3
4 Ω / Bridged
126
x2
Table 7.4d: C 5:4X Current Draw and Thermal Dissipation specifications
C 5:4X
Line Current *2)
Watt *1)
230 VAC
In
Out
6
0
51
0
Amp
Watt
0,9
176
63
0,8
156
63
0,7
152
63
0,7
134
63
0,7
131
63
0,5
94
32
1,6
330
125
1,3
265
125
1,2
252
125
1,1
222
125
1,1
228
125
0,7
139
63
Thermal Dissipation
Dissipated
BTU/hr
kCal/hr
6
20
5
51
312
79
114
387
98
94
319
80
89
305
77
72
244
62
68
233
59
62
213
54
205
700
176
140
476
120
127
433
109
97
331
83
103
350
88
76
260
65

Hide quick links: