Maytag MLG33 Installation & Operator's Manual page 14

Maytag compact dryer installation/operator manual
Hide thumbs Also See for MLG33:
Table of Contents

Advertisement

Heat Input/Gas Consumption/Orifice (Injector) Data (For Non-CE [European] Models Only)
Gas Specifications for Non-CE Approved
Gas Type and
Nominal Heating Value
Natural
*Liquid Propane
Shaded areas are stated in metric equivalents
*
Gas valve's internal regulator disabled.
** Information is per pocket/tumbler.
*** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)
Gas Type and
Nominal Heating Value
B tu /ft
Natural (I
/I
)
1,000
2H
2E
Natural (I
)
830
2L
Natural (I
)
830
2 E L L
1,000
*Natural (I
)
2E+
830
*Butane (I
)
3,175
3+
*Propane (I
)
2,500
3+
Butane (I
)
3,175
3B/P
Propane (I
)
2,500
3P
Shaded areas are stated in metric equivalents
*
Gas valve's internal regulator disabled.
** Information is per pocket/tumbler.
*** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
NOTES _____________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
____________________________________________________________________________________________
14
Supply
Pressure
B tu /ft
in WC
3
1,000
7.0-13.0
2,500
11.0
Gas Specifications for CE Approved
Supply
**Gross
Pressure
Heat Input
3
mb
Btu/hr
15-30
55,000
20-35
55,000
15-30
55,000
20
55,000
25
55,000
28-30
55,000
37
55,000
28-30/50
55,000
28-30/50
55,000
**Gross
Orifice Size
Heat Input
Btu/hr
kW
DMS
55,000
16.12
20
55,000
16.12
44
**Fuel
Consumption
kW
16.12
1.557 M
/H
3
16.12
1.876 M
/H
3
16.12
1.876 M
/H
3
16.12
1.557 M
/H
3
16.12
1.876 M
3
/H
16.12
1.162 kg/H
16.12
1.162 kg/H
16.12
1.162 kg/H
16.12
1.162 kg/H
Maytag Co.
Dryers***
Burner
**Orifice
Pressure
(Injector)
Quantity
mm
in WC
4.089
1
2.184
1
Dryers***
**Orifice
Orifice Size
(Injector)
Quantity
DMS
mm
3.988
22
1
3.988
22
1
3.988
22
1
3.048
31
1
31
3.048
1
48
1.930
1
48
1.930
1
44
2.184
1
2.184
44
1
3.0
10.0
Burner
Pressure
mb
6.9
9.5
9.5
18.1
24.9
113413 - 11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents