Ariston CLAS HE R 12 Installation And Servicing Instructions page 45

Gas fired condensing wall hung boiler
Hide thumbs Also See for CLAS HE R 12:
Table of Contents

Advertisement

description
4 ZONE 1 PARAMETER
4 0 ZONE 1 TEMPERATURE SETTING
4 0 0 Zone 1 comfort temperature
setting "Comfort ambience T"
4 0 1 Zone 1 reduced temperature
setting "Reduced ambience T"
4 0 2 Heating fixed temperature
setting "Heating fixed temp"
4 1 Entering access code
4 2 ZONE 1 SETTING
4 2 0 Heating appliance
temperature value setting
4 2 1 Basic heating control type
selection type depending
on the peripheral devices
connected
4 2 2 Slope
If the external sensor is
used, the boiler calculates
the most suitable heating
flow temperature taking the
external temperature and
the type of appliance into
account.
The type of curve must be
chosen according to the type
of appliance radiator and the
heat losses present in the
building.
4 2 3 Parallel shift
To adapt the thermal curve to the appliance requirements, it is possible to perform a parallel shift of the curve in order to alter the
calculated flow temperature and therefore the ambient temperature.
The shift value between - 0 and + 0 is shown on the display. Each level corresponds to a 1°C increase in the flow temperature
in relation to the initial setting.
4 2 4 Compensation
4 2 5 Zone 1 heating maximum
temperature setting
4 2 6 Zone 1 heating minimum
temperature setting
4 3 DIAGNOSTICS
4 3 0 Zone 1 room temperature
4 3 1 Zone 1 set temperature
4 3 2 Zone 1 heat request
4 3 3
NOT PRESENT
4 4 ZONE DEVICE MANAGEMENT
4 4 0
NOT PRESENT
settings - adjustment - problem identification menus
value
from 10 to 30 °C
from 10 to 30 °C
from 0 to 8 °C
0 = from 0 to 45°C (low temperature)
1 = from 35 to 85°C (high temperature)
0 = fixed flow temperature
1 = device On/Off
 = ambient sensor only
3 = external sensor only
4 = ambient sensor + external sensor
0_ to 3_5
°C
100
90
80
70
60
50
40
30
- 0 to + 0
0 to + 0
if setting = 0, the temperature taken from the ambient sensor does not affect the calculation
of the setting. If setting = 0, the temperature taken has maximum influence on the setting.
35 to + 8°C
0 to + 45°C
35 to + 8°C
0 to + 45°C
0=OFF
1=ON
19 Activated only with the modulating
device connected (option)
16
70 Activated only with temperature
control and fixed temperature
 press the programming "+" button
to select 34 and press the m
button
1 select in the appliance type base
1 To activate heating control, press
the AUTO button. The Auto light is
illuminate
1_5
3.5
3.0
2.5
2.0
1.5
1.2
1.0
0.8
0.6
0.4
0.2
10
5
0
-5
-10
-15
-20 °C
External temperature
temperatura esterna
0
0
8 if parameter 40 = 1
45 if parameter 40 = 0
35 if parameter 40 = 1
0 if parameter 40 = 0
display only
Activated only with the modulating
device connected (option)
eNu
45