Ariston CLAS HE R 12 Installation And Servicing Instructions page 28

Gas fired condensing wall hung boiler
Hide thumbs Also See for CLAS HE R 12:
Table of Contents

Advertisement

installation
TWIN-PIPE SYSTEM
S1 = Air intake S = Flue gas exhaust
S1 = S - Air intake and flue gas exhaust equal lengths
S1 + S - Air intake and flue gas exhaust unequal lengths
8
FLUE TYPE
C13
Flue gas exhaust and air
suction duct through
external wall in the same
range of pressure
C 33
Flue gas exhaust and air
suction duct from outside
with the roof terminal
in the same range of
pressure
C53
Flue gas exhaust leading
outside and air suction
duct through external
wall not in the same
range of pressure
MAX
DIAMETER
LENGTH
of PIPE
48 m
1
(S1=S)
4 m
18
80/80
(S1=S)
36 m
4
(S1=S)
80 m
1
(S1=S)
70 m
18
80/80
(S1=S)
60 m
4
(S1=S)
11 m
1
(S1+S)
98 m
18
80/80
(S1+S)
84 m
4
(S1+S)
Equivalent
length
45°
90°
0.5 m
1 m

Advertisement

Table of Contents
loading

Table of Contents