Download Print this page
Agilent Technologies 66309B/D Specifications
Agilent Technologies 66309B/D Specifications

Agilent Technologies 66309B/D Specifications

Mobile communications dc sources 40-100 w
Hide thumbs Also See for 66309B/D:

Advertisement

Quick Links

Application Specific DC Power Supplies tailored solutions for specific needs
66319B/D, 66321B/D
Overcome Battery Powered
Device Testing Challenges
Digital communications devices
and digital battery powered devices
present a unique testing challenge:
they draw rapid pulses of current.
By offering superior transient
performance, unmatched in the
marketplace, the Agilent Mobile
Communications DC Sources
dramatically reduce the transient
voltage drop due to pulse loading
characteristics of digital communi-
cations devices. The Agilent Mobile
Communications DC Sources enable
you to maximize test throughput by
minimizing test interruption due to
false trigger of device low voltage
shutdown.
Dynamic Measurement Capabilities
The Agilent Mobile Communications
DC Sources offer a built-in advanced
measurement system to accurately
measure battery current drains
when the device operates in differ-
ent modes (such as talk mode, active
mode, standby mode, and off/sleep
mode). Measurements made during
these modes are critical for ensuring
that your devices are operating
properly and that you are getting
the most out of the battery.
Simulate both Main Battery and Charger
Single output models are recom-
mended when you need to provide
power as a replacement to your
Mobile Communications DC Sources
40-100 W
Ideal for testing wireless and battery powered devices
Several times improvement in measurement throughput over general purpose DC sources
Superior output transient performance with short or long load leads (up to 6 meters)
Dynamic measurement system for accurate battery current drain measurement
New easy-to-use Graphical User Interface and analysis tools for bench top use
Specifications
66309B/D 66311B
˚
˚
(at 0
to 55
C unless
otherwise specified)
Number of outputs
2
GPIB
Yes
Output ratings
Voltage
0 to 15 V
Current
0 to 3 A
Peak current for up to 7 ms
5 A
Programming accuracy
at 25°C ±5°C (% of setting plus fixed)
Voltage
0.05%+
10 mV
+Current
0.05%+
1.33 mA
Ripple and Noise (20 Hz to 20 MHz)
Voltage
rms
1 mV
peak-to-peak
6 mV
Current
rms
2 mA
DC measurement accuracy
Voltage
0.03%+
5 mV
+20 mA to + rated current 0.2%+
0.5 mA
-20 mA to - rated current
0.2%+
1.1 mA
-3 A to + 5 A
0.2%
-1 A to + 1 A
0.1%
-20 mA to + 20 mA range 0.1%+
2.5 µA
Dynamic measurement system
Buffer size
4096 points 4096 points 4096 points 4096 points 4096 points 4096 points
Sampling interval
15 µs -
31,200 s
Transient response time
<35 µs
Transient voltage dip
70 mV
(typical with up to 15 feet
22 AWG wiring)
Programmable output resistance
Range
—-
Programming accuracy
Resolution
More detailed specifications at www.agilent.com/find/66300
81
66319B/D 66321B/D 66332A
1
2
1
Yes
Yes
Yes
0 to 15 V
0 to 15 V
0 to 15 V
0 to 3 A
0 to 3 A
0 to 3 A
5 A
5 A
5 A
10 mV
10 mV
10 mV
1.33 mA
1.33 mA
1.33 mA
1 mV
1 mV
1 mV
6 mV
6 mV
6 mV
2 mA
2 mA
2 mA
5 mV
5 mV
5 mV
2
2
0.5 mA
1.1 mA
2
2
0.5 mA
0.5 mA
0.2 mA
0.2 mA
2.5 µA
2.5 µA
2.5 µA
15 µs -
15 µs -
15 µs -
31,200 s
31,200 s
31,200 s
3
3
3
<35 µs
<20 µs
<20 µs
70 mV
40 mV
40 mV
-40 mΩ to
-40 mΩ to —
+1 Ω
+1 Ω
0.5% +
0.5% +
2 mΩ
2 mΩ
1 mΩ
1 mΩ
66332A-
J01
Special Order
Option
1
1
Yes
Yes
0 to 20 V
0 to 30 V
0 to 5 A
0 to 3.3 A
5 A
3.3 A
10 mV
15 mV
2 mA
2 mA
0.3 mV
0.5 mV
3 mV
5 mV
2 mA
2 mA
3 mV
5 mV
0.5 mA
0.5 mA
1.1 mA
1.1 mA
2.5 µA
2.5 µA
15 µs -
15 µs -
31,200 s
31,200 s
4
4
<100 µs
<100 µs
500 mV
650 mV

Advertisement

loading

Summary of Contents for Agilent Technologies 66309B/D

  • Page 1 0.5 mV characteristics of digital communi- peak-to-peak 6 mV 6 mV 6 mV 6 mV 3 mV 5 mV cations devices. The Agilent Mobile Current 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA Communications DC Sources enable...
  • Page 2 GPIB data is 4 ms (with Bluetooth enabled devices, and display disabled). 66309B/D, 66311B: Up to 4 V can be Wireless LAN access devices. dropped in each load lead. Add 2 mV to the load regulation specification for each 1 V drop in the positive output lead.
  • Page 3 < 2 ms (400 µs in fast mode). For 66311B, 66321B/D: 1.7 A, 125 W. measurements The output voltage change settles within For 66309B/D, 66319B/D: 2 A, 170 W. Current sinking for testing and • 1 LSB (0.025% x full scale voltage) of For 66332A: 3.5 A, 250 W.
  • Page 4 Ordering Information Accessories p/n 1494-0060 Rack Slide Kit Opt 100 87 to 106 Vac, 47 to 63 Hz * Opt 1CM Rack-mount kit 66309B/D, (66332A only) 66311B, 66319B/D, 66321B/D: Opt 120 104 to 127 Vac, 47 to 63 Hz E3663AC Support rails for p/n 5062-3972;...
  • Page 5 Application Specific DC Power Supplies tailored solutions for specific needs Mobile Communications DC Sources 40-100 W (Continued) Agilent Models: 666332A 364.4mm 14.3" Terminal Strip Detail Output 2 & 3 - -S Screw Size: M35 x 0.6 88.1mm 100mm 3.5" 3.93" Side 425.4mm 16.75" Rear More detailed specifications at www.agilent.com/find/66300...
  • Page 6 Easy-to-use Graphical User Interface and analysis tools No programming required Waveform Capture Mode Simplify test and analysis in Zoom capability R&D or on the repair bench With the Agilent 14565B Device Power Supply Characterization Software, testing, output analyzing, and troubleshooting...
  • Page 7 • analysis. The 14565B can be archive or analysis by other controlled from various programs software packages and programming languages such as the Agilent Wireless Test Manager, For Repair NI LabView , Agilent VEE, Micro- Compact design with multiple •...

This manual is also suitable for: