Download Print this page
Fluke 66 Specifications
Fluke 66 Specifications

Fluke 66 Specifications

Infrared thermometers non-contact temperature measurement
Hide thumbs Also See for 66:

Advertisement

Quick Links

The Fluke 66 and 68
Infrared Thermometers
Non-contact temperature measurement
The professional's diagnostic tool
The Fluke 66 and Fluke 68 non-contact thermometers
are the ideal professional diagnostic tools for HVAC
technicians performing room balance checks, electricians
evaluating electrical connections and auto mechanics
diagnosing catalytic converters. This handheld portable
tool enables professionals to research heating and venti-
lation problems, monitor the status of electrical motors
and electrical panels and diagnose car malfunctions with
ease. They measure surface temperatures, helping to
quickly locate potential blockages or malfunctioning
systems reducing work time and improving performance.
The 60 series thermometers feature:
Laser guided sighting system for easy targeting with
1 % accuracy.
12-point data logging.
Advanced optics to measure smaller targets at greater
distances.
Adjustable emissivity for more accurate temperature
measurements.
Selectable MAX, MIN, DIF and AVG functions that
display values instantly with Hi/Lo Alarm.
Temperatures up to 760 ºC (1400 ºF) (68).
Optical resolution
The laser sighting system guides measure-
ments to the right target and indicates the
approximate center of the measurement area.
(D:S = distance to spot using 90 % encircled energy at focal point).
D:S = 30:1
at focal point
0.9" @
1.2" @
12"
36"
D
Use the Fluke 66 within 5 m (15 ft.) of the intended target.
At greater distances, the measured area will be larger
(approximately the distance divided by 30).
D:S = 50:1
at focal point
S
2.5" @
0.8" @
60"
12"
Use the Fluke 68 within 8 m (25 ft.) of the intended target.
At greater distances, the measured area will be larger
(approximately the distance divided by 50).

Technical Data

S
0.7" @
1.7" @
60"
36"
D

Advertisement

loading

Summary of Contents for Fluke 66

  • Page 1: Technical Data

    12" 36" 36" Use the Fluke 66 within 5 m (15 ft.) of the intended target. Use the Fluke 68 within 8 m (25 ft.) of the intended target. At greater distances, the measured area will be larger At greater distances, the measured area will be larger (approximately the distance divided by 30).
  • Page 2: Specifications

    Fax (31 40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com/ ©2004 Fluke Corporation. All rights reserved. Printed in U.S.A. 5/2004 2153543 D-ENG-N Rev A...

This manual is also suitable for:

68