Output - GBC Titan 1244WF Installation & Operating Manual

Gbc laminator operation manual
Table of Contents

Advertisement

GBC 1264WF/1244WF
- A -
Fig. 24
- A -
Fig. 25
- A -
Fig. 26
© 2006 General Binding Corporation
Heat
The "READY" indicator may extinguish if the speed is set
too fast for the material being laminated. Either lower the
speed setting or press STOP and wait until the "READY"
indicator illuminates. Operation of the laminator for more
than thirty minutes at a time may necessitate a lower speed
setting. It is recommended that, during periods of long runs,
the items being laminated are alternated between thick and
thin. Do not combine thick and thin items at the same time,
as this will result in a poor edge seal around the thinner
material. If you are unsure that the laminator is set at the
proper speed for the item to be laminated, run a test piece
- B -
(scrap) of the same or similar material through the
Laminator. This procedure is recommended because
rotating the heat roller prior to lamination will more evenly
distribute the heat.
Make speed adjustments if necessary.

Output

1. "D" waves in the image (Fig. 24 A&B).
2. "D" waves in the laminate (Fig. 24 A&B).
- B -
3. Straight waves in output (Fig. 25 A).
4. Indent waves in output after pull rollers. (Fig. 25 B)
5. Angled waves in the output. (Fig. 26 A&B)
- B -
Operation Manual
Check paper tension.
Paper may be damp or not dry.
Check main roller pressure.
Check pull roller pressure.
Check operational settings for materials being
used.
Check clutch tension.
Insufficient cooling time.
Output was handled prior to cooling.
Use cooling feature if not on.
Machine was stopped on print.
Main air Supply setting
Check main Roller Pressure.
Check main roller pressure.
Check pull roller pressure.
Check for Paper Tension.