Zanussi ZEI3921IBA User Manual page 13

Product manaul
Hide thumbs Also See for ZEI3921IBA:
Table of Contents

Advertisement

Available languages

Available languages

Manufacturer is not responsible for any injury to persons
and pets or damage to property caused by failure to obey
these requirements.
Electrical connection
• Ground the appliance according to safety precautions.
• Make sure that the rated voltage and type of power on
the rating plate agree with the voltage and the power of
the local power supply.
• Any electrical component must be installed or replaced
by the Service Force Centre technician or qualified
service personnel.
• Always use a correctly installed shockproof socket.
• Make sure that there is an access to the mains plug af-
ter installation.
• Do not pull the mains cable to disconnect the appli-
ance. Always pull the mains plug.
• The appliance must not be connected with an extension
cable, an adapter or a multiple connection (risk of fire).
Check that the ground connection is in conformity with
the standard and regulations force.
• Connect the appliance to the mains with a device that
lets to disconnect the appliance from the mains at all
poles with a contact opening width of minimum 3 mm,
eg. automatic line protecting cut-out, earth leakage
trips or fuse.
• None of a parts of the connection cable can not get a
temperature 90°C. The blue neutral cable must be con-
nected to the terminal block label with "N". The brown
(or black) phase cable (fitted in the terminal block con-
tact marked with "L") must always be connected to the
live phase.
Replacement of the connection cable
To replace the connection cable use only H05V2V2-F T90
or equivalent type. Make sure that the cable section is ap-
plicable to the voltage and the working temperature. The
yellow/green earth wire must be approximately 2 cm lon-
ger than the brown (or black) phase wire.
www.zanussi.com
Assembly
min. 650 mm
If several 30 cm hobs are to be installed side by side into
the same cut out, an assembly kit including a support side
bracket and supplementary seals is available at our Serv-
ice Centres. The relevant installation instructions are sup-
plied within the kit package.
R 5
mm
+1
490
mm
490 mm
270 mm
600
mm
270
+1 mm
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zei3921

Table of Contents